Original Size Sensor; Removing The Original Sensor (Vertical Scan Direction) (When The Original Size Detection Sensor Is Equipped For Book Mode); Contact Sensor Hp Sensor - Canon iR2422 series Service Manual

Table of Contents

Advertisement

4) Pull the drive belt (front) [1] in the direction of the arrow to move he con-
tact sensor [2] to the center.
5) Remove the contact sensor HP sensor [3] together with the mount.
- Screws [4] 2pcs.
6) Remove the contact sensor HP sensor.
[4]

4.4.7 Original Size Sensor

4.4.7.1 Removing the Original Sensor (Vertical Scan
Direction) (When the original size detection sensor is
equipped for BOOK mode)
1)Open the copyboard glass cover or ADF.
2) Remove the copyboard glass.
3) Remove the cover [1].
- Screw [2] 1 pc.
[1]
[2]
[3]
F-4-54
[1]
[2]
F-4-55
4) Remove the flexible cable [1] from the reader controller PCB.
5) Remove the cover [1].
- Screw [2] 1 pc.
6) Pull the drive belt (front) left direction to move the contact sensor to the
left.
7) Remove the connector [1], and then remove the harness [2] from the har-
0020-4405
ness guide.
[1]
F-4-56
[2]
[1]
F-4-57
[2]
[1]
F-4-58
Chapter 4
4-25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir2318 seriesIr2420 seriesIr2320 series

Table of Contents