Panasonic WH-SDF03E3E5 Series Design Handbook page 78

Hide thumbs Also See for WH-SDF03E3E5 Series:
Table of Contents

Advertisement

Project Design
Planning of installation room
Assembly conditions and minimum distances from hydromodule
Minimum distances from the hydro-
module to walls, ceiling and floor
Note
The compressor is located in
the outdoor unit of the bi-bloc
system. The only noise from the
hydromodule will solely come
from circulation pump operation.
1
Minimum distance 300 mm
Minimum distance 600 mm
2
Example of an installation
room with a hydromodule
and hot water tank
WH-TD20E3E5
Note
Because of an installation room
volume of 6.25 m³ in the example,
it is suitable only for Aquarea LT
single phase devices up to 9 kW
heating capacity. The use of
a device with a larger amount
of refrigerant would exceed
the practical limit value c
(for R410A c = 0.44 kg / m³ and
for R407C c = 0.31 kg / m³)
Hot water tank
1
2
Hydromodule
3
Hot water
Cold water
4
Door
5
78
1
1
1
2
2,100
200
580
400
3
1
4
400
200
1
~ 2.5 m²
Aquarea air / water heat pump – design handbook 07 / 2014
502
400
2
Side view
2
400
5
Top view

Hide quick links: