Panasonic WH-SDF03E3E5 Series Design Handbook page 128

Hide thumbs Also See for WH-SDF03E3E5 Series:
Table of Contents

Advertisement

Appendix
Heating capacity in relation to supply water and outside temperature
Aquarea HT
Outside temperature
-15
-7
2
7
25
-15
-7
2
7
25
-15
-7
2
7
25
-15
-7
2
7
25
Heating capacity [kW] of individual models of the bi-bloc system for different supply water and outside temperatures [°C].
¹
Preliminary specifications
128
Supply water temperature
30
35
40
9 .0
9,0
8,9
9,0
9,3
9,0
9,0
8,9
9,0
9,0
9,2
9,0
12,0
12,0
12,0
10,8
30
35
40
12,0
11,2
11,0
10,6
12,0
11,9
11,5
11,2
12,0
11,5
11,5
10,5
12,0
11,6
12,0
11,5
12,0
12,0
12,0
12,0
30
35
40
9,0
9,0
8,9
9,0
9,0
9,0
9,0
9,0
9,0
9,0
9,0
9,0
12,0
12,0
12,0
10,8
30
35
40
12,0
12,0
11,0
10,6
12,0
12,0
11,5
11,2
12,0
12,0
11,5
11,3
12,0
12,0
12,0
12,0
12,0
12,0
12,0
12,0
45
50
55
60
8,8
8,5
8,5
8,0
8,9
8,9
9,3
8,9
8,3
9,0
9,0
9,0
9,2
9,0
8,8
9,0
10,2
11,2
10,0
45
50
55
60
10,3
9,7
9,0
10,8
10,2
9,9
11,0
10,8
10,7
12,0
11,7
12,0
12,0
12,0
12,0
45
50
55
60
8,8
8,5
8,5
8,0
8,9
8,9
8,9
8,9
9,0
9,0
9,0
9,0
9,0
9,0
9,0
9,0
10,2
11,2
10,0
45
50
55
60
10,3
9,7
9,0
10,8
10,1
9,9
11,0
10,8
10,7
12,0
12,0
12,0
12,0
12,0
12,0
Aquarea air / water heat pump – design handbook 07 / 2014
Models
65
9 kW (single phase)
WH-SHF09F3E5¹
7,8
WH-SHF09D3E5
8,9
(Phase-out models)
9,0
9,0
9,8
65
12 kW (single phase)
WH-SHF12F6E5¹
8,0
WH-SHF12D6E5
9,6
(Phase-out models)
10,3
12,0
12,0
65
9 kW (three phase)
WH-SHF09F3E8¹
7,8
WH-SHF09D3E8
8,9
(Phase-out models)
9,0
9,0
9,8
65
12 kW (three phase)
WH-SHF12F9E8¹
8,0
WH-SHF12D9E8
9,6
(Phase-out models)
10,3
12,0
12,0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wh-sdc03e3e5 seriesWh-sdf05e3e5 seriesWh-sdc07f3e5 seriesWh-sdc09f3e5 seriesWh-sdc09f3e8 seriesWh-sdc05e3e5 series ... Show all

Table of Contents