Panasonic WH-SDF03E3E5 Series Design Handbook page 55

Hide thumbs Also See for WH-SDF03E3E5 Series:
Table of Contents

Advertisement

OFF / ON-LED
1
Illuminates during operation and flashes
upon occurrence of an error
REMOTE display
2
Symbol is displayed when an external
room thermostat is connected and
activated
SOLAR display
3
Symbol is displayed when an external
solar thermal installation is connected
and activated
FORCE display
4
Symbol is displayed when the FORCE
mode is activated (additional electric
heater can heat)
HEATER display
5
Symbol is displayed when the additional
electric heater is activated (additional
electric heater can heat)
TANK display
6
Symbol will be shown during the hot
water mode (Aquarea heat pump
heating the tank)
COOL display
7
Symbol will be shown during the cooling
mode (Aquarea heat pump cooling)
HEAT display
8
Symbol will be shown during the heating
mode (Aquarea heat pump heating)
AUTO display
9
Symbol is shown during automatic
operation
TIMER display
10
Shows the setting of the 24-hour timer
for each weekday with clock
OUTDOOR display
11
Shows the current outside temperature
WATER OUTLET display
12
Shows the current output water
temperature of the Aquarea heat pump
HEATER display
13
Symbol is displayed when the additional
electric heater is in operation
Display and operating keys for easy operation and programming of the Aquarea control via the controller or wired remote control
(Bi-Bloc or monobloc system)
Note
Aquarea air / water heat pump – design handbook 07 / 2014
9
8
7
6
5
4
3
2
1
BOOSTER display
14
Symbol is displayed when the electric
immersion heater in the hot water tank is
in operation
QUIET display
15
Symbol will be shown when the quiet
mode is activated
SETTING display
16
Symbol will be displayed when
parameters in the settings are set
STATUS display
17
Symbol will be displayed when values
are depicted in the status menu
SERVICE display
18
Symbol is displayed in service mode
OFF / ON key
19
Starts or stops the operation of the unit
MODE key
20
Serves for setting the operation mode:
Heating, Heating + Hot water, Hot water,
Cooling + Hot water or Cooling
STATUS keys
21
For checking the system status
(compressor frequency, fault history,
return water temperature, tank tem-
perature)
The illustrated control panel applies to units of the new F generation. Units of
the older generations up to the E generation have a different control panel
(see next page).
As the same operator control panel is used for different devices, some functions
may not apply for your device.
Structure of the new F generation units
10
11
12
29
28
27
26
25
24
SERVICE key
22
For the activation of the circulation pump
and the pump down operation
HEATER key
23
For activating the additional
electric heater
ERROR RESET key
24
For the reset of the remote controller
or wired remote control and for
acknowledging the error code
HOLIDAY key
25
For setting the holiday mode with
energy-saving operation for a
configurable number of days
QUIET key
26
For the activation of quiet mode
with reduced noise production
SETTING key
27
For setting the heating curve, the
heating limit temperature, the cooling
temperature as well as the hot water
temperature and functions
FORCE key
28
For activating the heat pump electric sub-
mersible heater (emergency operation)
TIMER keys
29
For setting the system time
Closed-loop control
13
14
15
16
17
18
19
20
21
23 22