Aquarea HP Slimline
2
3
7
9
6
Typical arrangement of component
kit shown fitted to the appliance for
clarity. Pipework to be supplied
and fitted by installer.
Aquarea air / water heat pump – design handbook 07 / 2014
Basic Appliance
1
1
Hot water draw off (22 mm) compression
Temperature & pressure relief valve 92 – 95°/ 6 bar
2
Hot water secondary return 22 mm (210 litre model only)
3
Immersion heater 1¾" BSP 3 kW
4
5
22 mm cold supply
Primary return (28 mm)
6
7
Primary flow (28 mm)
Dual control / Overheat stat
8
HP control thermostat
9
8
Part G3 loose components supplied in a separate box
A
Combination inlet group incorporating pressure reducing valve, strainer,
check valve, balance cold take off point, expansion relief valve and
5
expansion vessel connection points.
4
B
Potable expansion vessels c/w flexible hose and wall bracket
C
Tundish
D
Dual control thermostat and combined overheat thermostat (× 2)
E
Three port motorised valve for primary circuit
F
Wiring junction box for primary system
Products, functions and technical data
Aquarea Heat Pump Slimline
Accessories