Lighting Instructions; Controls - Napoleon NPS45 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

8.4

LIGHTING INSTRUCTIONS

After fi lling the hopper with pellets, switch the control to manual so that you have full control of the appliance
until you have familiarized yourself with its functions.
Do not try to operate your appliance with the viewing door or hopper lid open. Safety switches will disable the
pellet feed auger.
A.
Press the "ON/OFF" button "ON" to initiate the ignition cycle.
B.
Once the ignition cycle has ended (approximately 12 to 15 minutes) adjustments can be made to the
control.
8.5

CONTROLS

RED LIGHTS
Solid
- Indicates set feed rates
- When making a fan
adjustment, light will indicate
fan speed temporarily and
return to heat setting.
Flashing
- Indicates an operation failure
HEAT ADJUSTMENT
Increases or decreases the heat
level.
AUGER FEED
Speed feeding of pellets into the
burn pot.
AUTO / T-STAT / MANUAL
This switch is used to select the operating mode.
MANUAL: Sliding the switch down to manual will allow you to manually select the heat and blower
settings. In manual mode the heater will run at your desired settings indefi nitely, until you manually turn
the heater off or the heater runs out of pellets.
T-STAT: If you would like to have your heater operate using a thermostat, slide the switch to the middle
position (T-STAT). In T-STAT mode the remote thermostat will control the heat output by alternating
between the lowest heat level and the preset heat level. When the thermostat setting is satisfi ed the
heater will default to the lowest heat level.
AUTO: Slide the switch to the top position (AUTO). Similar to T-STAT mode, auto operates using a
thermostat. The difference being if the thermostat does not call for heat in a 60 minute period the
heater will turn off completely. When the thermostat does call for heat, it will initiate a start-up cycle.
This operating mode is recommended for the spring and fall season, as the heater is only required
periodically.
POWER
5
AUGER
AUTO
T-STAT
MANUAL
1
HEAT
FAN
AUGER
ON
FEED
OFF
RED LIGHT
Start up Cycle
GREEN LIGHT
Solid
- Normal operating mode
Flashing
- Idling at lowest heat level.
AMBER LIGHT
Auger is turning.
OPERATING MODE
Sets the heater's operating mode.
FAN ADJUSTMENT
Increases or decreases the speed
of the convection fan.
ON / OFF
Used to turn the heater on or off.
W415-1472 / 04.21.15
33
EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Npi45

Table of Contents