Siemens SINAUT MD720-3 System Manual page 49

Gprs/gsm-modem
Hide thumbs Also See for SINAUT MD720-3:
Table of Contents

Advertisement

AT+CMGR
Read SMS message
Test
Command:
AT+CMGR=?
Response:
OK
Executive command
Command:
AT+CMGR=<index>
Response:
In text mode (+CMGF=1)
If command is executed successfully and SMS-DELIVER:
+CMGR: <stat>,<oa>,<scts>,<length>
<CR><LF><data><CR><LF>
If command is executed successfully and SMS-SUBMIT:
+CMGR: <stat>,<da>,<length>
<CR><LF><data><CR><LF>
In other cases:
+CMS ERROR: <err>
In PDU mode (+CMGF=0) and successfully performed command:
+CMGR: <stat>,[<alpha>],<length><CR><LF><pdu>
OK
Parameter:
Refer to +CMGL
Notice:
Execution command returns message with location value <index> from preferred
message storage <mem1>. Status of the message and entire message data unit <pdu> is
returned. If status of the message is 'received unread', status in the storage changes to
'received read'.
SINAUT MD720-3
C79000-G8976-C211
SINAUT MD720-3 in Terminal Mode
49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents