Siemens SINAUT MD720-3 System Manual page 34

Gprs/gsm-modem
Hide thumbs Also See for SINAUT MD720-3:
Table of Contents

Advertisement

SINAUT MD720-3 in Terminal Mode
AT\Q
Hardware Flow Control on/off
Executive command
Command:
AT\Q<n>
Response
OK
Parameter:
<n>:
0:
3:
Notice:
-
ATX
Set CONNECT result code Format und Call monitoring
Executive command
Command:
ATX[<value>]
Response:
OK
Parameter:
<value>:
0 :
1 :
2 :
3 :
4 :
Notice:
The term "tone" is used in analogue telephone networks. The status "No dialtone" will
usually not appear, as soon as the device is booked into a GSM network. A Busy
message will be transmitted.
AT&C
AT&C Set circuit Data Carrier Detect (DCD) function mode
Executive command
Command:
AT&C[<value>]
OK
Response:
Parameter:
<value>:
0 :
1 :
-
Notice:
34
Hardware Flow Control (RTS/CTS) off
Hardware Flow Control (RTS/CTS) on
CONNECT result code only returned, dial tone and busy detection are both
disabled <Default>
CONNECT<text> result code only returned, dial tone and busy detection are
both disabled
same as 1
same as 1
same as 1
DCD line is always ON
DCD line is ON in the presence of data carrier only. <Default>
SINAUT MD720-3
C79000-G8976-C211