Chapter 2
Installing the Device
Figure 10: Failsafe Alarm Relay Wiring
1. Normally Open
2. Common
Section 2.4
Grounding the Device
The RX1500 chassis ground terminal uses a #10-32 screw. It is recommended to terminate the ground
connection with a #10 ring lug and torque it to 3.4 N·m (30 lbf·in).
Figure 11: Chassis Ground Connection
1. #10-32 Screw
2. #10 Ring Lug
Section 2.5
Connecting to the Device
The following describes the various methods for accessing the ROX II console and Web interfaces on the device.
For more detailed instructions, refer to the ROX II User Guide for the RX1500.
Serial Console and Management Ports
Connect a PC or terminal directly to the serial console or management ports to access the boot-time control and
ROX II interfaces. The serial console port provides access to ROX II 's console interface, while the management
port provides access to ROX II's console and Web interfaces.
14
3. Normally Closed
1
2
3
1
2
RUGGEDCOM RX1500
Installation Guide
Grounding the Device