Download Print this page

Toshiba RAS-B10EKVP-E Service Manual page 112

Split type
Hide thumbs Also See for RAS-B10EKVP-E:

Advertisement

Ilmalämpöpumppujen myynti, huolto ja asennus: Jäähdytinpalvelu RefGroup Oy.
No.
Photo / Explanatory diagram
1-5
Valve fixing plate
1-6
1-7
Lue lisää nettisivuiltamme: www.ilmalämpöpumput.com
Remove the motor base assembly, partition plate assembly
and the sound insulation board.
Motor base
assembly
Related parts / Screws list
Partition plate
assembly
Part name
Motor base assembly
(Including motor and fan)
Partition plate assembly
Sound
(Including reactor)
insulation board
Remove the fixing screws of the heat exchanger and the
valve fixing plate. Remove the compressor fixing bolt.
Heat exchanger
Related parts / Screws list
Part name
Heat exchanger
Valve fixing plate
Compressor
Compressor
As shown in the left figure, remove the set of refrigeration cycle
assembly from the outdoor unit base plate.
* In this time, work attentively so that the cycle pipes are
not damaged by dent or deformation. Apply protective
measures to pipes if necessary.
Appendix-5
Procedure
Used screw
Screw type
Quantity
Ø4 × 8
2
Ø4 × 8
3
Used screw
Screw type
Quantity
Ø4 × 8
1
Ø4 × 8
1
bolt
3
Appendix