Download Print this page

Refrigerant Cycle Diagram - Toshiba RAS-B10EKVP-E Service Manual

Split type
Hide thumbs Also See for RAS-B10EKVP-E:

Advertisement

Ilmalämpöpumppujen myynti, huolto ja asennus: Jäähdytinpalvelu RefGroup Oy.

7-1. Refrigerant Cycle Diagram

RAS-B10EKVP-E/RAS-10EAVP-E
P
Pressure measurement
Gauge attaching port
Vacuum pump connecting port
Deoxidized copper pipe
Outer dia. : 9.52mm
Thickness : 0.8mm
4-way valve
(STF-0108Z)
TS
Temp. measurement
NOTE :
• The maximum pipe length of this air conditioner is 25 m. When the pipe length exceeds 15m, the additional
charging of refrigerant, 20g per 1m for the part of pipe exceeded 15m is required. (Max. 200g)
Lue lisää nettisivuiltamme: www.ilmalämpöpumput.com
7. REFRIGERANT CYCLE DIAGRAM
INDOOR UNIT
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
Outer dia. : 6.35mm
Thickness : 0.8mm
Sectional shape
of heat insulator
Muffler
Muffler
TD
Compressor
DA111A1F-20F1
Outdoor heat
exchanger
T2
Propeller fan
OUTDOOR UNIT
– 19 –
T1
Temp. measurement
TC
TA
Strainer
Pulse motor
valve at liquid side
(CAM-B22YGTF-2)
Strainer
TO
TE
NOTE :
Max. : 25m
Chargeless : 15m
Charge : 20g/m
(16 to 25m)
Refrigerant amount : 0.82kg
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)

Hide quick links:

Advertisement

loading