Hapter; Modular Cabinet - Dlu Cabling; Introduction; Installation - Nortel DCT1900 Technical Product Manual

Nortel networks technical product manual telephone dct1900
Table of Contents

Advertisement

C
24

HAPTER

Modular Cabinet – DLU Cabling
24.1

Introduction

This chapter describes the installation of the cabling between the DLU(s) and the PBX.
cable set, AWS1019, consists of (12) 2 pair cables individually terminated in a RJ11 connector.
Each DLU cable is designed to connect two DLU boards, thus 24 digital extensions, to a single 66
Block. The cable terminates in a 25 pair male AMP connector which mates with a Siemens
66m250 Block or the connector can be cut off and the cables punched down on other types of
blocks. Refer to Table 24-1 for a pin out of the cable
The Modular Cabinet is provided with a ground strip to connect the cables from the DLUs and the
CLUs to ground. These ground connections are necessary for EMI suppression reasons.
24.2

Installation

The 24 connectors on the DLU end of the cables are labelled P1 through P24 and should be
installed as shown in Fig. 24-2. Connector 1 goes to the first port of the DLU which is at the bottom
of the board. The male AMP is connected to the 66 Block.
The orientation of the shielding clamps should be as shown in Fig. 24-1.
Install-DCT1900/R8/mw
© 2000-2005
Fig. 24–1 Ground Strip with Shielding Clamps
Technical Product Manual - DCT1900
Installation Instructions, Modular Cabinet – DLU Cabling
Shielding clamp at the back row
Shielding clamps at the front row
The DLU
24-1