Nortel DCT1900 Technical Product Manual page 225

Nortel networks technical product manual telephone dct1900
Table of Contents

Advertisement

7 3/16"
Front
16.2
Base Station Cabling
Each Base Station requires a minimum of 2 pairs of CAT3 unshielded twisted pair cable. These
two pair will be SC0 (signalling channel 0) and SC1 (signalling channel 1). Besides being used for
signalling there is also 48 volts provided between the two pair to power the Base Station. One pair
is at a -48V potential with respect to the other pair.
How far a Base Station may be powered on the two pair is shown in a chart in Section 4, Chapter
4, Table 4-3. If the cable distance to the Base Station exceeds the value in the chart for 2 pair,
then the EPP (Express Power Pair) may be used. The EPP is a third pair of wires brought out of
the Radio Exchange that supplies -48V. The EPP contains two wires, EPP0 and EPP1, where
EPP1 is positive with respect to EPP0.
Install-DCT1900/R8/mw
© 2000-2005
3"
6 5/16"
LED1
LED2
label
Back
Fig. 16-1 Base Station Cover and Back
Technical Product Manual - DCT1900
Installation Instructions, Base Station – KRC 101 1371
RJ11
Back
Front
}
RJ45
16-3

Advertisement

Table of Contents
loading

Table of Contents