5.15
Changing the display unit % to A (ampere)/V (volt)
: Current/voltage unit selection
• Function
These parameters are used to change the unit of monitor display.
% ⇔A (ampere)/V (volt)
Current 100% = Inverter's rated current
Voltage 100% = 500Vac ( if is set in)
Example of setting
During the operation of the VFAS1-6022PL (rated current 4.0A) at the rated load (100% load), units are displayed
as follows:
1) Display in percentage terms
5
[Parameter setting]
Title
* The converts the following parameter settings:
• A display
• V display
Note: Base frequency voltage 1~4 (, , , ) is always displayed in the unit of V.
575Vac ( Default setting or if is set in)
690Vac ( if is set in)
Output current:
100%
DC voltage:100%
Function
Current/voltage unit selection
Current monitor display
Setting of electronic thermal protection level 1/2/3/4 , , , ,
DC braking current
Stall prevention level
Voltage monitor display
V/f 5-point setting
2) Display in amperes/volts
*
*
if
if
Adjustment range
: %
: % → A (ampere)/V (volt)
, , , ,
E-26
E6581528
Output current:
4.0A
DC voltage:575V
(Converted into AC
voltage)
was set in
was set in
Default setting