Braking Function - Toshiba TOSVERT VF-AS1 Instruction Manual

High-performance inverter
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

6. 17

Braking function

 : Braking mode selection
 : Load portion torque input
selection
 : Hoisting torque bias input
 : Lowering torque bias multiplier
• Function
These parameters can be used as brake sequences for lifts and similar equipment.
To ensure smooth operation, the motor produces enough torque before the brake is released.
Title

Braking mode selection
Load portion torque input

selection
Hoisting torque bias input (valid

only when =)

Lowering torque bias multiplier

Brake release time

Creeping frequency

Creeping time

Braking time learning function
Starting procedure
At the run command, the inverter makes the motor produce the torque specified with parameter . As soon
as a torque output command is issued, a brake release request signal is put out through the brake output terminal.
Upon expiration of the brake release time set with , the motor starts to accelerate.
Function
:Disabled
:Forward winding up
:Reverse winding up
:Horizontal operation
:Disabled
:VI/II (voltage/current input)
:RR/S4 (potentiometer/voltage input)
:RX (voltage input)
: enabled
:2-wire RS485 input enabled
:4-wire RS485 input enabled
:Communications option input enabled
:Optional AI1 (differential current input)
-~ %
~ %
~ sec. 
~ Hz
~ sec. 
:Disabled
:Brake signal learning (0 after adjustment)
F-29
 : Brake release time
 : Creeping frequency
 : Creeping time
 : Braking time learning function
Adjustment range
E6581528
Default setting


6





