Using the BayStack 350 10/100/1000 Series Switch
Table 3-26.
TELNET Configuration Screen Fields
Field
Description
TELNET Access Allows a user remote access to the CI through a TELNET session.
Default Value:
Range:
Login Timeout
Specifies the amount of time a user has to enter the correct password at the
console-terminal prompt.
Default Value:
Range:
Login Retries
Specifies the number of times a user can enter an incorrect password at the
console-terminal prompt before terminating the session.
Default Value:
Range:
Inactivity
Specifies the amount of time the session can be inactive before it is terminated.
Timeout
Default Value:
Range:
Event Logging
Specifies the types of events that will be displayed in the Event Log screen (see
Event
Default Value:
Range:
Description:
3-68
Enabled
Enabled, Disabled
1 minute
0 to 10 minutes (0 indicates "no timeout")
3
1 to 100
15 minutes
0 to 60 minutes (0 indicates "no timeout")
Log" on
page
3-74).
All
All, None, Accesses, Failures
All: Logs the following TELNET events to the Event Log screen:
TELNET connect: Indicates the IP address and access mode of a
TELNET session.
TELNET disconnect: Indicates the IP address of the remote host
and the access mode, due to either a logout or inactivity.
Failed TELNET connection attempts: Indicates the IP address of
the remote host whose IP address is not on the list of allowed
addresses, or indicates the IP address of the remote host that did
not supply the correct password.
None: Indicates that no TELNET events will be logged in the Event
Log screen.
Accesses : Logs only TELNET connect and disconnect events in the
Event Log screen.
Failures: Logs only failed TELNET connection attempts in the Event
Log screen.
"Display