Bay Networks BayStack 350 Using Manual page 127

Nortel networks baystack user guide
Table of Contents

Advertisement

Table 3-4
Table 3-4.
System Characteristics Screen Fields
Field
MAC Address
Reset Count
Last Reset Type
Power Status
sysDescr
sysObjectID
sysUpTime
sysServices
sysContact
sysName
sysLocation
* Although this field can be set to up to 255 characters from a Network Management Station (NMS), only 56 characters
are displayed on the console terminal.
304376-B Rev 00
describes the System Characteristics screen fields.
Description
The MAC address of the BayStack 350 switch.
A read-only field that indicates the number of resets since the operational firmware
was first loaded on the switch.
Default Value:
1
Range:
0 to 2
A read-only field that indicates the last type of reset.
Default Value:
Power Cycle
Range:
Power Cycle, Software Download, Management Reset,
Management Factory Reset
A read-only field that indicates the current power source.
Default Value:
Primary Power
A read-only field that specifies the hardware and software version.
A read-only field that provides a unique identification of the switch, which contains the
vendor's private enterprise number.
A read-only field that shows the length of time since the last reset. This field is
updated when the screen is redisplayed.
A read-only field that indicates the switch's physical and data link layer functionality.
The name and phone number of the person responsible for the switch.
Default Value::
Zero-length string
Range:
Any ASCII string of up to 56 printable characters*
A name that uniquely identifies the switch.
Default Value::
Zero-length string
Range:
Any ASCII string of up to 56 printable characters
The physical location of the switch.
Default Value:
Zero-length string
Range:
Any ASCII string of up to 56 printable characters
-1
32
Using the Console Interface
*
3-15