  • Page 2: What To Do If You Smell Gas

    WARNING • ALL RANGES CAN TIP • INJURY TO PERSON COULD RESULT • INSTALL ANTI-TIP DEVICE PACKED WITH RANGE • SEE INSTALLATION INSTRUCTIONS WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
  • Page 3: Important - Please Read And Follow

    IMPORTANT - PLEASE READ AND FOLLOW Before beginning, please read these instructions completely and carefully. Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty. Please observe all local and national codes and ordinances. Please ensure that this product is properly grounded.
  • Page 4: Installation Instructions

    INSTALLATION INSTRUCTIONS WARNING! THIS APPLIANCE HAS TO BE INSTALLED BY A QUALIFIED INSTALLER. Improper installation, adjustment, alteration, services, or maintenance can cause injury or property damage. Consult a qualified installer, service agent, or the gas supplier. IMPORTANT: The use of suitable protective clothing/gloves is recommended when handling, installing of this appliance. TOOLS NEEDED FOR INSTALLATION T-handle Tape...
  • Page 5: General Information

    GENERAL INFORMATION WARNING!! National Fuel Gas Code ELECTRICAL GROUNDING INSTRUCTIONS The range must be electrically grounded in accordance with local codes or, in the absence of local codes, with the Manufactured Home Construction National Electrical Code, ANSI/NFPA No. 70-latest edition. and Safety Standard, Title 24 CFR, Part 3280 [formerly Installation should be made by a Iicensed electrician.
  • Page 6 installation PROXIMITY TO SIDE CABINETS 1. This range may be installed directly adjacent to existing 36" (914 mm) high base cabinets. • width: 23” 7/8 (606.5 mm) • depth: 24” 5/64 (611.6 mm) • height (without backguard): MIN 35” 7/16 (900 mm) - MAX 36” 7/32 (920 mm) •...
  • Page 7: Assembling The Backguard

    PROXIMITY TO SIDE CABINETS Fig. 1.3a Fig. 1.3b Fig. 1.4 ASSEMBLING THE BACKGUARD It is mandatory to install the backguard Assemble the backguard as shown in figure 1.5: • Screw the 2 screws “A” interposing the spacers. • Screw the central screw “B”. Fig.
  • Page 8: Anti-Tip Stability Device Installation Instructions

    LEVELLING THE RANGE The range is equipped with 4 LEVELLING FEET (SUPPLIED IN A SEPARATE KIT) and may be levelled by screwing or unscrewing the feet with a spanner (fig. 1.8). It is important to observe the directions of figures 1.6, 1.7a, 1.7b. Fig.
  • Page 9: Gas Connection

    gas connection All gas connections must be made according to national and local codes. This gas supply (service) line must be the same size or greater than the inlet line of the appliance. Sealant on all pipe joints must be resistant to te action of LP/Propane gas.
  • Page 10 PRESSURE REGULATOR INSTALLATION STEP 1 Mount the 1/2” NPT (conical) male connector to the pressure regulator and tighten by using a wrench. LOCK Do not over tighten the connector. Over tightening may crack regulator. Arrow Fig. 2.2 STEP 2 Assemble the 1/2” NPT connector + pressure regulator group to the extension pipe interposing the gasket supplied. The regulator cover must be oriented toward the front side of the range.
  • Page 11 GAS CONNECTION SPECIFICATION Range manifold Manifold male pipe fitting 1/2” G cylindrical (ISO 228-1) male 1/2” G cylindrical Gasket (ISO 228-1) female To range Extension pipe female pipe fitting Extension pipe Extension 1/2” G cylindrical pipe male (ISO 228-1) male pipe fitting 1/2”...
  • Page 12: Leak Testing

    To range b) Any conversion required must be performed by your dealer or a qualified licensed plumber or gas service company. Please provide the service person with this manual before work is started on the range. (Gas conversions are the responsibility of the dealer or end user.) c) This range can be used with NATURAL or LP/PROPANE gas.
  • Page 13: Conversion To Lp/Propane Gas

    CONVERSION TO LP/PROPANE GAS Every range is provided with a set of injectors for the various types of gas. Select the injectors to be replaced according to the “INJECTORS TABLE”. The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each injector.
  • Page 14: Injectors Table

    INJECTORS TABLE NOMINAL REDUCED LP/PROPANE NATURAL GAS POWER POWER 11” W.C.P. 4” W.C.P. Ø injector Ø injector BTU/hr BTU/hr BURNERS [1/100 mm] [1/100 mm] Auxiliary (AUX) 3500 1000 Semirapid (SR) 6000 1500 Triple ring (TC) 12000 5000 Oven burner 13000 1500 Broil burner 8500...
  • Page 15 OPERATIONS TO BE EXECUTED FOR THE REPLACEMENT OF THE INJECTORS OF THE OVEN AND BROIL BURNERS Oven Burner – Lift and remove the lower panel inside the oven. – Remove the burner securing screw (fig. 2.10). – Withdraw the burner as shown in figure 2.11 and rest it inside the oven. Take care not to damage the wire to the ignition electrode and the safety valve probe.
  • Page 16: Adjustment Of The Oven Burner Minimum

    ADJUSTMENT OF THE OVEN BURNER MINIMUM This needs to be done only for the oven burner (the broil is a fixed capacity) by acting on the thermostat in the following way: – Turn on the burner by setting the thermostat knob on position –...
  • Page 17: Electrical Connection

    electrical connection If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. Check with a qualified electrician if you are not sure whether the range is properly grounded.
  • Page 18: Wiring Diagram

    WIRING DIAGRAM...