Si06-313
1.6

Removal of the Fan Rotor / Fan Motor

Procedure
before disassembling work.
Step
For removal of the
1
drain
pan, disconnect
the drain hose, then
dismount the two
screws located at left
and right sides.
Remove the drain pan.
2
To remove the
swing
3
motor
on discharge
port of the drain pan,
dismount the two fixing
screws.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
Procedure
Indoor Unit
Points
Be careful not to wet the
floor with drain water.
Disengage harness for drain
pan from right side hook.
This swing motor is for down
flow shutter.