Si06-313
1.2

Heat Pump

Indoor Units
Model
Outdoor Units
Capacity
Moisture Removal
Running Current
Power Consumption
Power Factor
COP
Liquid
Piping
Gas
Connections
Drain
Heat Insulation
Indoor Unit
Front Panel Color
Air Flow Rate m³/min
(cfm)
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current
Power Consumption
Power Factor
Temperature Control
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/M/L/SL
Sound
Sound Power H
Outdoor Unit
Casing Color
Type
Compressor
Model
Motor Output
Model
Refrigerant
Oil
Charge
Model
Refrigerant
Charge
Air Flow Rate m³/min (cfm)
Type
Fan
Motor Output
Running Current
Power Consumption
Power Factor
Starting Current
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/L
Sound
Sound Power H
Drawing No.
Notes:
Specifications
Cooling
kW
4.8 (0.9~5.3)
Btu/h
16,390 (3,070~18,090)
kcal/h
4,130 (770~4,560)
L/h
2.9
A
7.5
W
1,700 (450~2,350)
%
98.6
W/W
2.82
mm
mm
mm
Both Liquid and Gas Pipes
H
10.8 (381)
M
9.2 (325)
L
7.7 (272)
SL
6.7 (237)
W
Steps
5 Steps, Silent and Auto
Right, Left, Horizontal and Upward
Removable / Washable / Mildew Proof
A
0.26
W
55
%
92.0
Microcomputer Control
mm
mm
kg
kg
dBA
44 / 40 / 36 / 33
dBA
56
Hermetically Sealed Swing Type
W
L
kg
H
47.7 (1,684)
L
44.1 (1,557)
W
A
7.20
W
1,645
%
99.3
A
mm
mm
kg
kg
dBA
47 / —
dBA
63
MAX. interunit piping length: 30m
MAX. interunit height difference: 20m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Cooling
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
SL : The silent fan level of the air flow rate setting.
230V, 50Hz
FVXS50BVMB
RXS50BVMB
Heating
6.0 (0.9~7.7)
20,480 (3,070~26,290)
5,160 (770~6,620)
8.2
1,870 (310~2,600)
99.2
3.21
φ
6.4
φ
12.7
φ
20.0
FVXS50BVMB
Almond White
13.2 (466)
11.3 (399)
9.4 (332)
8.3 (293)
Cross Flow Fan
14+14
0.32
70
95.1
600×650×195
714×770×294
13
19
45 / 40 / 36 / 33
57
RXS50BVMB
Ivory White
2YC32HXD
1,500
FVC50K
0.65
R410A
1.20
44.1 (1,557)
44.1 (1,557)
Propeller
53
7.90
1,800
99.1
7.5
735×825×300
784×960×390
49
53
48 / —
64
3D040831
Heating
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
Specifications
FVXS50BVMB
RXS50BVMA
Cooling
4.8 (0.9~5.3)
6.0 (0.9~7.7)
16,390 (3,070~18,090)
20,480 (3,070~26,290)
4,130 (770~4,560)
5,160 (770~6,620)
2.9
7.2
1,700 (450~2,350)
1,870 (450~2,800)
98.4
2.82
φ
6.4
φ
12.7
φ
20.0
Both Liquid and Gas Pipes
FVXS50BVMB
Almond White
10.8 (381)
9.2 (325)
7.7 (272)
6.7 (237)
Cross Flow Fan
14+14
5 Steps, Silent and Auto
Right, Left, Horizontal and Upward
Removable / Washable / Mildew Proof
0.25
55
91.7
Microcomputer Control
600×650×195
714×770×294
13
19
44 / 40 / 36 / 33
45 / 40 / 36 / 33
56
RXS50BVMA
Ivory White
Hermetically Sealed Swing Type
2YC32HXD
1,500
FVC50K
0.65
R410A
1.20
47.7 (1,684)
44.1 (1,557)
44.1 (1,557)
44.1 (1,557)
Propeller
53
6.95
1,645
98.6
7.9
735×825×300
784×960×390
48
53
47 / 44
63
3D040832
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Piping Length
7.5m
240V, 50Hz
Heating
7.9
98.6
3.21
13.2 (466)
11.3 (399)
9.4 (332)
8.3 (293)
0.31
70
94.1
57
7.59
1,800
98.8
48 / 45
64
7