ALARM/
ALARM
ALERT
OR
CODE
ALERT
Critical Serial EEPROM
A156
Alarm
Storage Failure
A157
Alarm
A/D Hardware Failure
Loss of communication
T170
Alert
with the Compressor
Expansion Module
Loss of Communication
A172
Alarm
with EXV Board
Loss of Communication
T173
Alert
with EMM
4 to 20 mA Cooling Set
T174
Alert
Point Input Failure
Loss of Communication
T175
Alert
with the AUX Board
4 to 20 mA
T176
Alert
Temperature Reset
Input Failure
4 to 20 mA Demand
T177
Alert
Limit Input Failure
Cooler Pump Auxiliary
A189
Alarm
Contact Inputs Miswired
Cooler Pump 1 Aux
T190
Alert
Contacts Failed to Close
at Start-Up
Cooler Pump 2 Aux
T191
Alert
Contacts Failed to Close
at Start-Up
Cooler Pump 1 Failed
T192
Alert
to Provide Flow at
Start-Up
Cooler Pump 2 Failed
T193
Alert
to Provide Flow at
Start-Up
Cooler Pump 1 Aux
Contacts Opened
T194
Alert
During Normal
Operation
Cooler Pump 2 Aux
Contacts Opened
T195
Alert
During Normal
Operation
Flow Lost While Pump 1
T196
Alert
Running
Flow Lost While Pump 2
T197
Alert
Running
See Legend on page 78.
Table 36 — Alarm and Alert Codes (cont)
WHY WAS THIS
DESCRIPTION
ALARM
GENERATED?
Configuration/storage
failure with MBB
Hardware failure with
peripheral device
MBB cannot communicate
with CXB
MBB loses communication
with EXV board
MBB loses communication
with EMM
If configured with EMM and
input less than 2 mA or
greater than 22 mA
MBB loses communication
with AUX Board.
If configured with EMM
and input less than 2 mA or
greater than 22 mA
If configured with EMM and
input less than 2 mA or
greater than 22 mA
Pump 1 Auxiliary Contacts
are closed when Pump 2
output is energized or if
Pump 2 Auxiliary Contacts
are closed when Pump 1
output is energized.
Pump 1 Auxiliary Contacts
did not close within
26 seconds after pump
was started
Pump 2 Auxiliary Contacts
did not close within
26 seconds after pump
was started
Pump 1 did not provide
flow to close flow switch
within 60 seconds
Pump 2 did not provide
flow to close flow switch
within 60 seconds
Pump 1 Auxiliary Contacts
open for 26 seconds after
initially made. All
compressors shut down.
Pump 1 turned off.
Pump 2 Auxiliary Contacts
open for 26 seconds after
initially made. All
compressors shut down.
Pump 2 turned off.
Cooler flow switch contacts
open for 3 seconds after
initially made
Cooler flow switch contacts
open for 3 seconds after
initially made
ACTION TAKEN
BY CONTROL
Chiller is not allowed
to run.
Chiller is not allowed
to run.
Compressor A1 shut
down
Chiller is not allowed
to run.
4 to 20 mA
temperature reset
disabled. Demand
Limit set to 100%. 4 to
20 mA set point
disabled.
Set point function
disabled. Chiller
controls to CSP1.
Chiller is not allowed
torun.
Reset function
disabled. Chiller
returns to normal set
point control.
Demand limit function
disabled. Chiller
returns to 100%
demand limit
control.
Both pump outputs
are turned off.
Pump 1 turned off.
Pump 2 will be started
if available.
Pump 2 turned off.
Pump 1 will be started
if available.
Pump 1 turned off.
Pump 2 will be started
if available.
Pump 1 turned off.
Pump 2 will be started
if available.
Pump 2 will be started
if available. Chiller
allowed to run if
Pump 2 successfully
starts.
Pump 1 will be started
if available. Chiller
allowed to run if
Pump 1 successfully
starts.
All compressors
shut down. Pump 1
turned off. Pump 2 will
be started if available.
Chiller allowed to run if
Pump 2 successfully
starts and flow switch
is closed.
All compressors shut
down. Pump 2 turned
off. Pump 1 will be
started if available.
Chiller allowed to run if
Pump 1 successfully
starts and flow switch
is closed.
76
RESET
PROBABLE
METHOD
CAUSE
Main Base Board
Manual
failure.
Main Base Board
Manual
failure.
Wiring error, faulty
wiring or failed CXB.
Automatic
Incorrect configura-
tion.
Wiring error, faulty
Automatic
wiring or failed
EXV board.
Wiring error, faulty
wiring or failed
Automatic
Energy Manage-
ment Module (EMM).
Faulty signal
Automatic
generator, wiring
error, or faulty EMM.
Wiring error, faulty
wiring or failed
Automatic
AUX board, incorrect
configuration.
Faulty signal
Automatic
generator, wiring
error, or faulty EMM.
Faulty signal
Automatic
generator, wiring
error, or faulty EMM.
Wiring error, faulty
Manual
pump contactor
auxiliary contacts.
Wiring error, faulty
Manual
contacts on pump
contactor
Wiring error, faulty
Manual
contacts on pump
contactor
Wiring error, pump
circuit breaker
Manual
tripped, contactor
failure
Wiring error, pump
circuit breaker
Manual
tripped, contactor
failure
Wiring error, faulty
Manual
contacts on pump
contactor
Wiring error, faulty
Manual
contacts on pump
contactor
Wiring error, pump
circuit breaker
Manual
tripped, contactor
failure
Wiring error, pump
circuit breaker
Manual
tripped, contactor
failure