18
CONTROL COMMAND
D Command table (continued)
Cmd. Sub Cmd. Data
1C
01
00
01
02
02
00
01
03
see
p. 18-11
04
00
01
1E
00
01
see
p. 18-13
02
03
see
p. 18-13
21
00
see
p. 18-13
01
00 or 01
02
00 or 01
25
see
p. 18-14
26
see
p. 18-14
27
00
see p. 18-15 Read the Scope waveform data
10
00 or 01
11
00 or 01
12
00 or 01
13
00 or 01
14
see p. 18-15 Send/read the Scope Center mode or Fixed
15
see p. 18-15 Send/read the span setting in the Center
16
see p. 18-15 Send/read the Edge number setting in the
17
see p. 18-15 Send/read the Scope hold function ON or
18
see p. 18-16 Send/read the Scope Attenuator setting
19
see p. 18-16 Send/read the Scope Reference level setting
1A
see p. 18-16 Send/read the Sweep speed setting
1B
00 or 01
1C
00 to 02
1D
see p. 18-16 Send/read the Scope VBW setting
1E
see p. 18-16 Send/read the Scope Fixed edge frequencies
Description
Send/read the antenna tuner OFF (through)
Send/read the antenna tuner ON
Send/read to tuning
Send/read transmit frequency monitor setting
OFF
Send/read transmit frequency monitor setting
ON
Read transmit frequency
*When "CI-V Output (for ANT)"
(Command:
1C
04) is set to "ON," automatically outputs
when changed.
Send/read command to disable to output the
antenna controller status (frequency and so
on) from [REMOTE]
Send/read command to enable to output the
antenna controller status (frequency and so
on) from [REMOTE]
Read number of available TX frequency
band
Read TX band edge frequencies
Read number of user-set TX frequency band
Send/read user-set TX band edge frequencies
Send/read RIT frequency
Send/read RIT setting (00=OFF, 01=ON)
Send/read ∂TX setting (00=OFF, 01=ON)
Send/read the Main or Sub band frequency
Send/read the selected operating mode and
filter
* Only when "Scope ON/OFF status"
(Command: 27 10) and "Scope data output"
(Command: 27 20) are set to "ON," outputs
the waveform data to the controller.
Send/read the Scope ON/OFF status
(00=Scope OFF, 01=Scope ON)
Send/read the Scope data output
(00=Output OFF, 01=Output ON)
*Only when "CI-V USB Port" is set to "Unlink
from [REMOTE]" and "CI-V USB Baud
Rate" is set to 115200 (bps), "Output ON" is
selectable.
Send/read the Main or Sub scope setting
(00=Main scope, 01=Sub scope)
Send/read the Single/Dual scope setting
(00=Single scope, 01=Dual scope)
mode setting
mode Scope
Fixed mode Scope
OFF
Send/read the Scope indication during TX in
the Center mode
(00=OFF, 01=ON)
Send/read scope center frequency setting in
the Center mode
( 00=Filter center, 01=Carrier point center,
02=Carrier point center (Abs. Freq.))