Lens file selection page
LENS:1
No Offset
On the first line, select the number of the lens file.
On the second line, the lens-file name corresponding to the
selected file is displayed.
The selected lens file will be retained until a new lens file
is selected. As long as the same lens is used, further
selection of the lens file is not required.
Note
All the lens files are named "No Offset," with all zero
settings at shipment. File registration and modification of
data in a lens file must be performed in Custom mode.
For details on the lens files, see "Chapter 5 Storage and
Retrieval of User Setting Data".
3-2-8 Confirmation of the Time Code
and Tape Remaining
When the SRW-1 HD Portable Digital Recorder is attached
to this camera, the time code of the recorder and
approximate tape remaining (unit: minutes) can be
confirmed on the subdisplay.
Time code/tape remaining display page
TCR 00:00:00:00
20min
The time code is displayed on the first line, and the
approximate tape remaining is displayed on the second
line, in the range of 1 to 99 min.
Time code that is displayed on the first line
Indication
Meaning
TCR 00:00:00:00 Time code data of the LTC reader
TCR 00:00.00:00 Time code data of the LTC reader (DF)
TCR.00:00:00:00 Time code data of the VITC reader
UBR 00 00 00 00 User bit data of the LTC reader
UBR.00 00 00 00 User bit data of the VITC reader
TCG 00:00:00:00 Time code data of the time code
generator
TCG 00:00:00.00 Time code data of the time code
generator (DF)
UBG 00 00 00 00 User bit data of the time code
generator
CTL -0:00:00:00 Data of the CTL counter
38
Basic Settings with the Subdisplay
Indication
Meaning
T*R 00:00:00:00 Time code cannot be read with the
LTC reader.
U*R 00 00 00 00 User bit cannot be read with the LTC
reader.
T*R.00:00:00:00 Time code cannot be read with the
VITC reader.
U*R.00 00 00 00 User bit cannot be read with the VITC
reader.
The type of the displayed time code data is linked with the
SRW-1. Select the type of the displayed time code data on
the SRW-1.
3-2-9 Confirmation of the Power
Voltage and Selection of Fan
Operation Mode
The values in voltage of the power sources connected to
the camera can be confirmed on the subdisplay.
On the same page, the operation mode of the built-in fans
can also be selected.
Voltage confirmation/Fan Operation mode select
page
1
11.4V
FAN:AUTO1
At 1 and 2 on the first line, the values in voltage of the
12-V and 24-V power systems are displayed, respectively.
If power is not supplied, "- -" is displayed.
If the voltage falls to the NEAR END level, the indication
starts flashing. If the voltage falls further down to the END
level, the indication flashes rapidly.
The NEAR END and END levels can be set on the <BATT
ALARM SET> page of the MAINTENANCE menu.
Selecting Fan Operation mode
On the second line, the operation mode of the built-in fans
can be changed according to the ambient temperature or
the operation mode of the recorder.