4.11 Configuration Copying Commands; Copy Wls8600 Series - Wasp WLS8600 Reference Manual

Hide thumbs Also See for WLS8600:
Table of Contents

Advertisement

4.11 CONFIGURATION COPYING COMMANDS

4.11.1

Copy WLS8600 Series

Procedure:
Connect the master (correctly configured reader) and the slave (reader to be
configured) together through two RS-232 serial interface cables and external
power supply.
RS-232 Cables: CAB471 & CAB472
Power Supply: PG5
Using the slave reader, read the Restore Default barcode and then the RS-232
interface barcode from chapter 3 of this manual or from the Quick Reference
Guide.
With the master reader, read the Configuration Copy barcode below.
The configuration will be copied from the master to the slave reader. The slave
reader signals the end of the procedure with a series of beeps.
NOTE: The master reader can be configured for any interface.
Copy Configuration
Ì$+ZZ0$-*Î
MESSAGE FORMATTING
115