Custom Default Configuration; 4.10 Code Type Recognition - Wasp WLS8600 Reference Manual

Hide thumbs Also See for WLS8600:
Table of Contents

Advertisement

WLS8600
4.9

CUSTOM DEFAULT CONFIGURATION

Read the following code to set the reader user-defined configuration as custom
default configuration:
Read the following code whenever you need to restore the custom default
configuration:

4.10 CODE TYPE RECOGNITION

This procedure allows the reader to enter a particular state during which it reads and
transmits to the Host information about the family type of codes unknown to the user
(with the exception of MSI, Code 49 and Code 16k code types). It is also possible to
read and transmit configuration strings without interpreting them.
All codes are read ignoring the check digit.
Follow the given procedure:
 Read the following code to enter the code type recognition mode:
Read existing codes whose family type you need to check.
 Read the following code to return to the reader's normal functioning:
114
Save User-defined Configuration as Custom Default
Ì$+$0ÂÎ
Restore Custom Default Configuration
Ì$+$1$Î
code type recognition
Ì#+CODEÂÎ
exit code type recognition mode
Ì$-?Î