Nikon D700 Repair Manual page 211

Hide thumbs Also See for D700:
Table of Contents

Advertisement

INC
△(Addition)
VBA22001-R.3754.A
③ X / Y inspection and adjustment
《USB or RS232C communication》
Caution : Whenever the AF sensor unit is disassembled/replaced or the penta-prism unit is disassembled or the mirror angle
is adjusted, be sure to make this adjustment.
【Procedure】
Procedure】 】
1. .Set the X chart.
2. Read the degree of rotation of the X-adjustment screw by the X-position inspection & adjustment.
3. Remove the front body, and loosen the three screws that fix the mounting plate.
4. Turn the X-adjustment screw through the degree of rotation which was read by ② ,then, apply the
screwlock to this screw.
5. Tighten the three screws to fix the mounting plate.
6. Mount the front body (#1509) on the rear body temporarily. Repeat the procedure from 2. to 5. until the result
becomes within standard. (Usually, the result meets the standard only once.)
7. When the adjustment is completed at 6, make the YAW/PITCH inspection & adjustment .
8. Make the XY inspection and adjustment.
X adjusting screw
Screw (#1509)×3
Device
J19123
J63098
   AF X-Y CHART FOR D3
SHUTTER TESTER EF-1(CE)
- A111 ・ D700 -
Changed page △× 1
August, 19,2008