INC
VBA22001-R.3754.A
Battery contact mold
・ Remove the mold (#56).
・ Tighten the three screws (#1567).
Screw (#1567) × 3
Mold (#56)
・ Mount the battery contact B unit (#B823).
・ Tighten the screw (#1595).
Screw (#1595)
Boss
Battery contact B unit (#B823)
・ FG contact unit (#B824).
・ Tighten the screw (#1595).
Screw (#1595)
FG contact unit (#B824)
Boss
- A2 ・ D700 -