Pgm Outputs; Main Pgm Output; Pc4204 Options; Pc4216 Options - DSC Maxsys PC4010 Programming Manual

Hide thumbs Also See for Maxsys PC4010:
Table of Contents

Advertisement

PGM
OUTPUTS

PGM OUTPUTS

(07)

Main PGM Output

The PGM output can be programmed to activate for any one of the 35 options listed in the PGM
MAIN PGM OUT
outputs list. Normally the output will be open collector (not active) and will switch to ground
(0)
potential (active). The output will switch from ground potential (active) to open collector (not
active) if any "INV" options are selected.
Notes: Refer to the PGM Outputs List for the available options.
If the Links Module is enabled the Main PGM Output cannot be programmed. The message
'LINKS Module is Active' will appear if the section is entered.

PC4204 Options

Each relay of any 4204 relay module can be programmed to activate for any one of the 35
4204 OPTIONS
options listed in the PGM outputs list. Normally each relay will be de-energized and energized
(1)
when active. The relay will normally be energized and then de-energized if any "INV" option is
selected. Output 1 will always be active if left at default of (19) COMBUS power. It will always be
active unless there is no incoming COMBUS power.

PC4216 Options

A maximum of nine 4216 output modules can be connected to the system.
4216 OPTIONS
First select the PC4216 to be programmed, then select the option it is going to be programmed
(2)
for. The PC4216 can be an alarm annunciator, a zone follower or one of nine custom PGM arrays.
The custom group allows each of the 16 outputs to be individually programmed with one of the 35
CUSTOM GROUP
options listed in the PGM outputs list. Each output is programmed in the "4216 CUSTOM" section.
(01)
(09)
The 4 selections of "ALARMS XX-XX" are for programming the PC4216 to annunciate alarms.
ALARMS 1-16
The 16 outputs will activate for each of the corresponding selected zones. The output will remain
(10)
active, even when the partition is disarmed, for continuously showing the zones which have gone
into alarm. The outputs will deactivate the next time the partition is armed.
For example, a PC4216 is programmed for Alarms 49-64. If zone 53 goes into alarm, the output
will activate and remain active even when the bells are silenced and the partition is disarmed.
The outputs will reset when the partition is armed again.
More than one PC4216 can be programmed to annunciate the same zones.
The 4 selections of "FOLLOW XX-XX" are for programming the PC4216 to annunciate open
zones.
The 16 outputs will activate for each of the corresponding selected zones. The output will activate
FOLLOW 1-16
when the zone is open, and deactivate when the zone is restored.
(14)
More than one PC4216 can be used to annunciate the same group of 16 zones. For example,
PC4216 #1 is programmed as Follow 33-48 and #5 is programmed as Follow 33-48. If zone 34 is
opened, output 2 on both 4216s will activate.
See "Follows + Alarms" for making outputs act as a zone follower and alarm annunciator.
36