System Times; Access Codes; Pgm Output Programming - DSC Envoy NT9005EU Installation & Programming Manual

32 zone security system
Table of Contents

Advertisement

Advanced Programming
[001] - [004] Zone Definitions
This section requires 32 two digit entries. Each two digit entry deter-
mines how the zone will operate. See Zone Definitions on the pre-
ceding page and Zone Attributes section [101]-[132].
Section
Zone
Default
[001]
01
02
03
04
05
06
07
08
[002]
09
10
11
12
13
14
15
16
[003]
17
18
19
20
21
22
23
24
[004]
25
26
27
28
29
30
31
32
24
FLASH
Zone Definition
01
I___I___I
03
I___I___I
03
I___I___I
03
I___I___I
04
I___I___I
04
I___I___I
04
I___I___I
04
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
00
I___I___I
firealarmresources.com

[005] System Times

Default
Entry Delay 1
030 I___I___I___I (000 - 255) seconds
Entry Delay 2
045 I___I___I___I (000 - 255) seconds
Exit Delay
120 I___I___I___I (000 - 255) seconds
Bell Cut-off
004 I___I___I___I (000 - 255) minutes

[006-008] Access Codes

All codes can be either 4 or 6 digits in length. The default is 4
digits. See section [701], option 5.
User codes and Duress codes are programmed via [*][5] pro-
gramming.
[
[006] Installer's Code
Change value to prevent unauthorized access to system.
Default
5555
I___I___I___I___I___I___I
[007] Master Code
The Master Code can perform any function. This code can be used
to program all access codes including the duress codes. If the Mas-
ter Code Not Changeable option in section [015][6] is enabled,
users will not be able to change the Master code.
Default
1234
I___I___I___I___I___I___I
[008] Maintenance Code
This is an Arm/Disarm only code. It cannot be used to activate [*][7]
outputs, program other user codes or enter the [*][6] menu. Open-
ings or closings using this code report as a Special Opening/Clos-
ing and will log to the event buffer as Maintenance Code.
Default
AAAA
I___I___I___I___I___I___I
[

[009-011] PGM Output Programming

PGM Outputs
Programmed in section [009]. Attributes are
1, 2
programmed in sections [141], [142]
PGM Outputs
Programmed in section [011]. Attributes pro-
11, 12, 13, 14
grammed in sections [151]-[154]
Unless indicated otherwise, attributes are as indicated below.
Attribute numbers not mentioned in the default section have
no impact on operation and are typically defaulted OFF.
Attribute
Function
ON
1
Enabled
Future Use
2
True Output
3
Output Pulsed
4
Code Required
5
Future Use
6-8
[*]
Function
OFF
Disabled
Inverted Output
ON/OFF
No Code Required