SYSTEM
OPTIONS
This section contains options that are relevant to the entire system. System Toggle options,

SYSTEM OPTIONS

Keypad Toggle options, Keypad Lockout options and System Time can all be programmed in this
(02)
section.
Sys Toggle Options
Toggle options are in question form. Use the [ ] key to toggle between Yes and No to enable or
SYS TOGGLE OPT
disable the feature. Use the [<] [>] keys to scroll through the options.
(0)
Changeable System Grand Master Code?
CHANGE SYS MAS
YES = System Grand Master Code can be changed by the end user via Grand Master Code.
Y
NO = The System Grand Master Code can only be changed via installer's programming.
Shunt Zones on Power Up?
POWER UP SHUNT
YES = All zones are considered non-violated by the main control for the first 2 minutes that
Y
NO = The zones are active upon power up.
AC Trouble Displayed?
AC TBL DISP
YES = The system will monitor and display an incoming AC power failure from the transformer.
Y
NO = The system will not display the incoming AC power failures.
Is the incoming AC Frequency 60 Hz?
60 H z LINE
YES = The incoming AC power from the transformer cycles at 60 Hz. The North American
Y
NO = The incoming AC power cycles at 50 Hz.
FOR FUTURE USE
N
AC inhibits arming?
AC INHIBIT ARM
YES = When an AC trouble condition is present on the main panel or PC4204, the system cannot be
N
NO = Regardless of the presence of an AC Trouble, the system can be armed.
DC inhibits arming?
DC INHIBIT ARM
YES = When a low battery condition is present on the main control panel or on a PC4204
N
No = No forced battery check will be performed and a Battery trouble will not inhibit arming.
Note: The Control panel and each of the PC4204 modules may only have 3 battery trouble
alarms in a 24 hour period. After the third battery trouble for a given module the trouble
condition will "Shutdown" until midnight of that day. The trouble will still be enunciated
with the keypad Trouble LED but the event will not be logged to the event buffer or be
communicated.
power has been applied to the system. This will allow time for the detectors to "settle"
without causing false alarms.
standard is 60 Hz.
armed, except by autoarm.
expansion module, the system can not be armed (DC Inhibit Arm does not apply to
wireless zone that have battery troubles). If the partition is attempted to be armed the
keypad display will show the message "Fail To Arm... DC Trouble". When an access code
is entered the panel will perform a battery check on the main control panel and on each of
the PC4204's enrolled on the system. This will ensure that the battery condition is good
before the panel is armed. If the control panel has a battery trouble or any one of the
PC4204's report back with a battery trouble the arming will be aborted.
SYSTEM AREA
SYSTEM OPTIONS
7
SYS TOGGLE OPT