  • Page 1 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 202-10010-01 November 2003 202-10010-01...
  • Page 2: Technical Support

    In the interest of improving internal design, operational function, and/or reliability, NETGEAR reserves the right to make changes to the products described in this document without notice. NETGEAR does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein.
  • Page 3: Canadian Department Of Communications Compliance Statement

    Canadian Department of Communications Compliance Statement This Class B Digital apparatus (GSM7224 Layer 2 Managed Switch) meets all the requirements of the Canadian Interference Causing Equipment Regulations. Cet appareil numerique del la classe B respect les exigences du Regalement sur le material broilleur du Canada. This device comples with Class B limits of Industry of Canada.
  • Page 4 202-10010-01...
  • Page 5: Table Of Contents

    Chapter 1 About This Guide Audience ...1-1 Why the Document was Created ...1-1 How to Use This Document ...1-1 Typographical Conventions ...1-2 Special Message Formats ...1-2 Features of the HTML Version of this Manual ...1-3 How to Print this Manual ...1-4 Chapter 2 Switch Management Overview Scope ...2-1...
  • Page 6 System-Wide Popup Menus ...5-4 Port-Specific Popup Menus ...5-4 Chapter 6 Quick Startup Quick Starting the Switch ...6-1 System Info and System Setup ...6-2 Quick Startup Software Version Information ...6-2 Quick Startup Physical Port Data ...6-3 Quick Startup User Account Management ...6-3 Quick Startup IP Address ...6-4 Quick Startup Uploading from Switch to Out-of-Band PC (Only XMODEM) ...6-6 Quick Startup Downloading from Out-of-Band PC to Switch (Only XMODEM) ...6-6...
  • Page 7 Management Commands ...7-13 show network ...7-13 config network macaddr ...7-13 config network mactype ...7-14 config network parms ...7-14 config network protocol ...7-14 config network webmode ...7-14 config network javamode ...7-15 config prompt ...7-15 show serial ...7-15 config serial baudrate ...7-16 config serial timeout ...7-16 show serviceport ...7-16 config serviceport parms ...7-16...
  • Page 8 config telnet mode ...7-22 config telnet timeout ...7-22 show forwardingdb agetime ...7-23 config forwardingdb agetime ...7-23 Device Configuration Commands ...7-23 show switchconfig ...7-24 config switchconfig broadcast ...7-24 config switchconfig flowcontrol ...7-24 show port ...7-24 config port adminmode ...7-25 config port flowcontrol ...7-25 config port linktrap ...7-26 config port physicalmode ...7-26 config port lacpmode ...7-26...
  • Page 9 config vlan port ingressfilter ...7-33 show protocol ...7-33 config protocol create ...7-33 config protocol delete ...7-33 config protocol protocol add ...7-34 config protocol protocol remove ...7-34 config protocol vlan add ...7-34 config protocol vlan remove ...7-34 config protocol interface add ...7-35 config protocol interface remove ...7-35 show garp info ...7-35 show garp interface ...7-35...
  • Page 10 config macfilter create ...7-43 config macfilter remove ...7-44 config macfilter addsrc ...7-44 config macfilter delsrc ...7-44 config macfilter adddest ...7-45 config macfilter deldest ...7-45 Spanning Tree Commands ...7-45 show spanningtree summary ...7-46 config spanningtree adminmode ...7-46 config spanningtree forceversion ...7-47 config spanningtree configuration name ...7-47 config spanningtree configuration revision ...7-47 show spanningtree port ...7-47...
  • Page 11 show spanningtree mst port summary ...7-55 show spanningtree mst port detailed ...7-55 show spanningtree vlan ...7-55 User Account Management Commands ...7-56 show users ...7-56 config users add ...7-56 config users passwd ...7-57 config users delete ...7-57 config users snmpv3 authentication ...7-57 config users snmpv3 encryption ...7-57 config users snmpv3 accessmode ...7-58 show loginsession ...7-58...
  • Page 12 config dot1x port initialize ...7-65 config dot1x port reauthenticate ...7-65 config dot1x port controldir ...7-66 config dot1x port controlmode ...7-66 config dot1x port quietperiod ...7-66 config dot1x port transmitperiod ...7-67 config dot1x port supptimeout ...7-67 config dot1x port servertimeout ...7-67 config dot1x port maxrequests ...7-67 config dot1x port reauthperiod ...7-67 config dot1x port reauthenabled ...7-68...
  • Page 13 transfer upload filename ...7-76 transfer upload datatype ...7-76 transfer upload start ...7-76 transfer download mode ...7-76 transfer download serverip ...7-77 transfer download path ...7-77 transfer download filename ...7-77 transfer download datatype ...7-77 transfer download start ...7-78 clear transfer ...7-78 clear config ...7-78 clear pass ...7-78 clear traplog ...7-78 clear vlan ...7-78...
  • Page 14 Appendix B Glossary Numeric ...10-1 A ...10-2 B ...10-2 C ...10-3 D ...10-4 E ...10-5 F ...10-6 G ...10-7 H ...10-8 I ...10-8 L ...10-9 M ...10-10 N ... 10-11 O ...10-12 P ...10-12 Q ...10-13 R ...10-13 S ...10-14 T ...10-16 U ...10-17 V ...10-17...
  • Page 15: About This Guide

    Thank you for purchasing the NETGEAR Audience This reference manual assumes that the reader has basic-to-intermediate computer and Internet skills. However, basic computer network, Internet, and wireless technology tutorial information is provided in the Appendices. This document describes configuration commands for the GSM7224 Layer 2 Managed Switch software.
  • Page 16: Typographical Conventions

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Note: Refer to the release notes for the GSM7224 Layer 2 Managed Switch Software application level code. The release notes detail the platform specific functionality of the Switching, SNMP, Config, and Management packages.
  • Page 17: Features Of The Html Version Of This Manual

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Features of the HTML Version of this Manual The HTML version of this manual includes these features. Figure Preface -2: HTML version of this manual 1. Left pane. Use the left pane to view the Contents, Index, Search, and Favorites tabs.
  • Page 18: How To Print This Manual

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software How to Print this Manual To print this manual you man choose one of the following several options, according to your needs. • Printing a “How To” Sequence of Steps in the HTML View. Use the Print button the upper right of the toolbar to print the currently displayed topic.
  • Page 19: Switch Management Overview

    This chapter gives an overview of switch management, including the methods you can use to manage your NETGEAR GSM7224 Layer 2 Managed Switch. • Management Access Overview • SNMP Access • Protocols Scope The GSM7224 Layer 2 Managed Switch software has two purposes: •...
  • Page 20 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software • Simple Network Protocol Management (SNMP) Each management method enables the network administrator to configure, manage, and control the GSM7224 locally or remotely using in-band or out-of-band mechanisms. Management is standards-based, with configuration parameters and a private MIB providing control for functions not completely specified in the MIBs.
  • Page 21: Command Line Interface Syntax

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software The Command Line Interface (CLI) syntax, conventions and terminology are described in this section. Each CLI command is illustrated using the structure outlined below. Format Commands are followed by values, parameters or both.
  • Page 22: Command

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Command The text in bold, non-italic font must be typed exactly as shown. Parameters Parameters are order dependent. The text in bold italics should be replaced with a name or number. To use spaces as part of a name parameter, enclose it in double quotes like this: "System Name with Spaces".
  • Page 23: Conventions

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software logical slot.port Conventions Network address are used to define a link to a remote host, workstation or network. Network addresses are shown using the following syntax: Table 1. Network Address Syntax...
  • Page 24: Annotations

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Annotations The CLI allows the user to type single-line annotations at the command prompt for use when writing test or configuration scripts and for better readability. The exclamation point (‘!’) character flags the beginning of a comment.
  • Page 25: Administration Console Telnet Interface

    Chapter 4 Administration Console Telnet Interface The administration console is an internal, character-oriented, VT-100/ANSI menu-driven user interface for performing management activities. Using this method, you can view the administration console from a terminal, PC, Apple Macintosh, or UNIX workstation connected to the switch’s console port.
  • Page 26 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Examples of terminal-emulation programs include: • HyperTerminal, which is included with Microsoft Windows operating systems • ZTerm for the Apple Macintosh • TIP for UNIX workstations This example describes how to set up the connection using HyperTerminal on a PC, but other systems follow similar steps.
  • Page 27 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software When the following screen appears, make sure that the port setting are as follows: Baud Rate: 9600 Data Bits: Parity: None Stop Bits: Flow Control: None Figure 4-4: Connection Settings Click OK.
  • Page 28 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Administration Console Telnet Interface 202-10010-01...
  • Page 29: Web-Based Management Interface

    Chapter 5 Web-Based Management Interface Your NETGEAR GSM7224 Layer 2 Managed Switch provides a built-in browser interface that lets you configure and manage it remotely using a standard Web browser such as Microsoft Internet Explorer 5.0 or later or Netscape Navigator 6.0 or later.
  • Page 30: How To Log In To The Gsm7224

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software • Device Management • Interface Operations • Product Overview • Summary of Features How to Log In to the GSM7224 The GSM7224 Layer 2 Managed Switch can be configured remotely from Microsoft Internet Explorer browser version 5.0 or above, or Netscape Navigator web browser version 4.78 or above.
  • Page 31: Web-Based Management Utility Features

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Type the default user name of admin and default of no password, or whatever password you have set up. Once you have entered your access point name, your Web browser should automatically find the GSM7224 L2 Switch and display the home page, as shown below.
  • Page 32: System-Wide Popup Menus

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software System-Wide Popup Menus The GSM7224 L2 Switch also provides several popup menus. You can also access the main navigation menu by right clicking on the image of the switch and browsing to the menu you want to use.
  • Page 33: Quick Startup

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software The Command Line Interface Quick Startup chapter details procedures to quickly become acquainted with the GSM7224 Layer 2 Managed Switch software. This chapter contains the following Quick Startup examples: •...
  • Page 34: System Info And System Setup

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software System Info and System Setup There are several categories of Quick Startup commands: • “Quick Startup Software Version Information” on page 6-2 • “Quick Startup Physical Port Data” on page 6-3 •...
  • Page 35: Quick Startup Physical Port Data

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Quick Startup Physical Port Data Quick Startup Physical Port Data Table 6-2. Command Details Displays the Port Characteristics show port all Slot.Port - slot number.port number Slot Options: 0 - the port is one of the physical ports 1 - a link aggregation group (LAG).
  • Page 36: Quick Startup Ip Address

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Table 6-3. Quick Startup User Account Management Command show loginsession config users passwd <user> save config logout Quick Startup IP Address To view the network parameters the operator can access the device by the following three methods.
  • Page 37 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Table 6-4. Quick Startup IP Address Command Details Default Gateway - The default Gateway for this interface Default value is 0.0.0.0 Burned in MAC Address - The Burned in MAC Address used for...
  • Page 38: Quick Startup Uploading From Switch To Out-Of-Band Pc (Only Xmodem)

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Quick Startup Uploading from Switch to Out-of-Band PC (Only XMODEM) Table 6-5. Quick Startup Uploading from Switch to Out-of-Band PC (Only XMODEM) Command transfer upload mode xmodem transfer upload datatype <config|errorlog|systemtrace|traplog>...
  • Page 39: Quick Startup Downloading From Tftp Server

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Quick Startup Downloading from TFTP Server Before starting a TFTP server download, the operator must complete the Quick Startup for the IP Address. Table 6-7. Quick Startup Downloading from TFTP Server...
  • Page 40: Vlan Configuration Example

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software VLAN Configuration Example This section provides configuration examples for VLAN configurations. LAN switches can segment networks into logically defined virtual workgroups.This logical segmentation is commonly referred as a virtual LAN (VLAN). This logical segmentation of devices provides better LAN administration, security, and management of broadcast activity over the network.
  • Page 41: Solution 1

    Devices on Project P should tag all traffic with 'VLAN 9' Solution 2 The network card configuration for devices on Project A, B and C should be set to NOT tag traffic. To take care of these untagged frames configure the following: •...
  • Page 42 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 6-10 Quick Startup 202-10010-01...
  • Page 43: Switching Commands

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software This chapter provides detailed explanation of the Switching commands. The commands are divided into five functional groups: • Show commands display switch settings, statistics, and other information. •...
  • Page 44: Numeric

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Switch Description Machine Type Machine Model Serial Number FRU Number Part Number Maintenance Level Manufacturer Burnedin MAC Address Software Version Operating System Network Processing Element The type of the processor microcode.
  • Page 45: Config Syslocation

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config syslocation This command sets the physical location of the switch. The range for the name is from 1 to 31 alphanumeric characters. Default Format config syscontact This command sets the organization responsible for the network. The range for the name is from 1 to 31 alphanumeric characters.
  • Page 46: Show Forwardingdb Learned

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Slot.Port if Index Status show forwardingdb learned This command displays the forwarding database entries for learned addresses. If the command is entered with no parameter, all learned addresses are displayed. This is the same as entering the optional parameter.
  • Page 47 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Octets Received - the total number of octets of data (including those in bad packets) received on the network (excluding framing bits but including FCS octets). This object can be used as a reasonable estimate of ethernet utilization.
  • Page 48 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Received Packets not forwarded Total - the total number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. Jabbers Received - the total number of packets received that were longer than...
  • Page 49 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Packets Transmitted Octets Packets Transmitted Successfully Transmit Errors Switching Commands CFI Discards - the number of frames discarded that have CFI bit set and the addresses in RIF are in non-canonical format.
  • Page 50 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Transmit Discards Protocol Statistics Total Errors - the sum of Single, Multiple, and Excessive Collisions. FCS Errors - the total number of packets transmitted that had a length...
  • Page 51: Show Stats Port Summary

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Dot1x Statistics Time Since Counters Last Cleared show stats port summary This command displays a summary of statistics for a specific port. Format Packets Received Without Error Packets Received...
  • Page 52: Show Stats Switch Detailed

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software show stats switch detailed This command displays detailed statistics for all CPU traffic. Format 7-10 show stats switch detailed Total Packets Received (Octets) - the total number of octets of data received by the processor (excluding framing bits but including FCS octets).
  • Page 53: Show Stats Switch Summary

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Time Since Counters Last Cleared show stats switch summary This command displays a count of all CPU traffic. Format Packets Received Without Error Broadcast Packets Received Packets Received...
  • Page 54: Show Eventlog

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software show eventlog This command displays the event log, which contains error messages from the system. The event log is not cleared on a system reset. Format File Line...
  • Page 55: Management Commands

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Management Commands These commands manage the switch and show current management settings. show network This command displays network configuration settings that are vital for switch operation. Format IP Address...
  • Page 56: Config Network Mactype

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software • Bit 7 of byte 0 (called the I/G bit) indicates whether the destination address is an individual address (b'0') or a group address (b'1'). • The second character, of the twelve character macAddr, must be 2, 6, A or E.
  • Page 57: Config Network Javamode

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Default Format config network javamode This command specifies whether or not the switch should allow access to the Java applet in the header frame of the Web interface. When access is enabled, the Java applet can be viewed from the Web interface.
  • Page 58: Config Serial Baudrate

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config serial baudrate This command specifies the communication rate of the terminal interface. The supported rates are 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200. Default Format config serial timeout This command specifies the maximum connect time (in minutes) without console activity.
  • Page 59: Show Snmpcommunity

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software show snmpcommunity This command displays SNMP community information. Six communities are supported. You can add, change, or delete communities. The switch does not have to be reset for changes to take effect.
  • Page 60: Config Snmpcommunity Create

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config snmpcommunity create This command adds (and names) a new SNMP community. A community name is a name associated with the switch and with a set of SNMP managers that manage it with a specified privileged level.
  • Page 61: Config Snmpcommunity Mode

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config snmpcommunity mode This command activates or deactivates an SNMP community. If a community is enabled, an SNMP manager associated with this community manages the switch according to its access right.
  • Page 62: Config Snmptrap Ipaddr

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config snmptrap ipaddr This command assigns an IP address to a specified community name. The maximum length of name is 16 case-sensitive alphanumeric characters. Note: IP addresses in the SNMP trap receiver table must be unique. If you make multiple entries using the same IP address, the first entry is retained and processed.
  • Page 63: Config Trapflags Authentication

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config trapflags authentication This command enables or disables the Authentication Flag. Default Format config trapflags bcaststorm This command enables or disables the broadcast storm trap. When enabled, broadcast storm traps are sent only if the broadcast storm recovery mode setting associated with the port is enabled (see “config switchconfig broadcast”...
  • Page 64: Show Telnet

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software show telnet This command displays telnet settings. Format Telnet Login Timeout (minutes) Maximum Number of Telnet Sessions Allow New Telnet Sessions config telnet maxsessions This command specifies the maximum number of telnet sessions that can be established. A value of 0 indicates that no telnet session can be established.
  • Page 65: Show Forwardingdb Agetime

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Default Format show forwardingdb agetime This command displays the timeout for address aging. In an IVL system, the [fdbid|all] parameter is required. In an SVL system, the [fdbid|all] parameter is not used and will be ignored if entered.
  • Page 66: Show Switchconfig

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software show switchconfig This command displays switch configuration information. Format Broadcast Storm Recovery Mode 802.3x Flow Control Mode config switchconfig broadcast This command enables or disables broadcast storm recovery mode. If the mode is enabled, broadcast storm recovery with high and low thresholds is implemented.
  • Page 67: Config Port Adminmode

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Format Slot.Port Type Admin Mode Physical Mode Physical Status Link Status Link Trap LACP Mode config port adminmode This command enables or disables a port. Default Format config port flowcontrol This command enables or disables flow control on the specified interface.
  • Page 68: Config Port Linktrap

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config port linktrap This command enables or disables link status traps by interface. Note: This command is valid only when the Link Up/Down Flag is enabled. See “config trapflags linkmode”...
  • Page 69: Config Lag Create

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Logical Slot.Port Lag Name Link State Admin Mode Link Trap Mode STP Mode Mbr Ports Port Speed config lag create This command configures a new LAG and generates a logical slot and port number for it. Display this number using the “show lag”...
  • Page 70: Config Lag Adminmode

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config lag adminmode This command enables or disables a LAG. The interface is a logical slot and port for a configured LAG. The option all sets every configured LAG with the same administrative mode setting.
  • Page 71: Show Vlan Summary

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software The mode is one of the following: 802.1d fast show vlan summary This command displays a list of all configured VLANs. Format VLAN ID VLAN Name VLAN Type...
  • Page 72: Config Vlan Create

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Current Configured Tagging config vlan create This command creates a new VLAN and assigns it an ID. The ID is a valid VLAN identification number (ID 1 is reserved for the default VLAN) VLAN range is 2-4094.
  • Page 73: Config Vlan Makestatic

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Default Format config vlan makestatic This command changes a dynamically created VLAN (one that is created by GVRP registration) to a static VLAN (one that is permanently configured and defined). The ID is a valid VLAN identification number.
  • Page 74: Show Vlan Port

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software show vlan port This command displays VLAN port information. Format Slot.Port Port VLAN ID Acceptable Frame Types Ingress Filtering GVRP config vlan port pvid This command changes the VLAN ID per interface.
  • Page 75: Config Vlan Port Ingressfilter

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Format config vlan port ingressfilter This command enables or disables ingress filtering. If ingress filtering is disabled, frames received with VLAN IDs that do not match the VLAN membership of the receiving interface are admitted and forwarded to ports that are members of that VLAN.
  • Page 76: Config Protocol Protocol Add

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config protocol protocol add This command adds the <protocol> to the protocol-based VLAN identified by <groupid>. A group may have more than one protocol associated with it. Each interface and protocol combination can only be associated with one group.
  • Page 77: Config Protocol Interface Add

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config protocol interface add This command adds the physical . If is selected, all physical interfaces will be added to this protocol group. A <groupid> <all> group may have more than one interface associated with it. Each interface and protocol combination can only be associated with one group.
  • Page 78: Config Garp Gmrp Adminmode

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Leave Timer LeaveAll Timer Port GMRP Mode Port GVRP Mode config garp gmrp adminmode This command enables or disables GARP Multicast Registration Protocol (GMRP) on the system. The default value is disable.
  • Page 79: Config Garp Gvrp Adminmode

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config garp gvrp adminmode This command enables or disables GVRP. Default Format config garp gvrp interface mode This command enables or disables GVRP (GARP VLAN Registration Protocol) for a specific port.
  • Page 80: Config Garp Leavealltimer

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config garp leavealltimer This command sets how frequently Leave All PDUs are generated per port. A Leave All PDU indicates that all registrations will be unregistered. Participants would need to rejoin in order to maintain registration.
  • Page 81: Config Igmpsnooping Adminmode

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config igmpsnooping adminmode This command enables or disables IGMP Snooping on the system. The default value is disable. Format config igmpsnooping groupmembershipinterval This command sets the IGMP Group Membership Interval time on the system. The Group Membership Interval time is the amount of time in seconds that a switch will wait for a report from a particular group on a particular interface before deleting the interface from the entry.
  • Page 82: Config Igmpsnooping Interface Mode

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config igmpsnooping interface mode This command enables or disables IGMP Snooping on a selected interface. The <slot.port/all> parameter identifies the interface on which to configure the mode. If an interface which has IGMP Snooping enabled is enabled for routing or is enlisted as a member of a LAG, IGMP Snooping functionality will be disabled on that interface.
  • Page 83: Show Mfdb Igmpsnooping

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Mac Address Type Description Interfaces show mfdb igmpsnooping This command displays the IGMP Snooping entries in the Multicast Forwarding Database (MFDB) table. Format Mac Address Type Description Interfaces...
  • Page 84: Show Mfdb Stats

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Description Interfaces show mfdb stats This command displays the Multicast Forwarding Database (MFDB) statistics. Format Total Entries Most MFDB Entries Ever Used Current Entries show mirroring This command displays the Port Mirroring information for the system.
  • Page 85: Config Mirroring Delete

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config mirroring delete This command removes the port mirroring designation from both the probe port and the mirrored port and removes the probe port from all VLANs. The port must be manually re-added to any desired VLANs.
  • Page 86: Config Macfilter Remove

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software The <vlan> parameter must identify a valid VLAN. Up to 100 static MAC filters may be created. Format config macfilter remove This command removes all filtering restrictions and the static MAC filter entry for the MAC address <macaddr>...
  • Page 87: Config Macfilter Adddest

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software If all is selected, all ports will be removed from the source port filter set. Format config macfilter adddest This command adds the <slot.port> to the destination filter set for the MAC filter with the given <macaddr>...
  • Page 88: Show Spanningtree Summary

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software • Show commands display spanning tree settings, statistics, and other information. • Config commands configure features and options of the switch. For every config command there is a show command that displays the config setting.
  • Page 89: Config Spanningtree Forceversion

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config spanningtree forceversion This command sets the Force Protocol Version parameter to a new value. The <version> can be one of the following: • 802.1d - ST BPDUs are transmitted rather than MST BPDUs (IEEE 802.1d functionality supported) •...
  • Page 90: Config Spanningtree Port Migrationcheck

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Port Up Time Since Counters Last Cleared STP BPDUs Transmitted STP BPDUs Received RST BPDUs Transmitted RST BPDUs Received MSTP BPDUs Transmitted MSTP BPDUs Received config spanningtree port migrationcheck This command forces the specified port to transmit RST or MST BPDUs.
  • Page 91: Config Spanningtree Bridge Maxage

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config spanningtree bridge maxage This command sets the Bridge Max Age parameter to a new value for the common and internal spanning tree. The maxage <value> is in whole seconds within a range of 6 to 40, with the value being less than or equal to "2 times (Bridge Forward Delay - 1)".
  • Page 92: Show Spanningtree Cst Port Summary

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Format Bridge Priority Bridge Identifier Time Since Topology Change Topology Change Count Topology Change Designated Root Root Path Cost Root Port Identifier Root Port Max Age Root Port Bridge...
  • Page 93: Show Spanningtree Cst Port Detailed

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software show spanningtree cst port detailed This command displays the settings and parameters for a specific switch port within the common and internal spanning tree. The <slot.port> is the desired switch port...
  • Page 94: Config Spanningtree Cst Port Priority

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config spanningtree cst port priority This command sets the Port Priority to a new value for use within the common and internal spanning tree. The <slot.port> is the desired switch port. The priority <value> is a number in the range of 0 to 240 in increments of 16.
  • Page 95: Config Spanningtree Mst Vlan Add

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config spanningtree mst vlan add This command adds an association between a multiple spanning tree instance and a VLAN. The VLAN will no longer be associated with the common and internal spanning tree. The instance <mstid>...
  • Page 96: Config Spanningtree Mst Port Priority

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config spanningtree mst port priority This command sets the priority for a specific port within a specific multiple spanning tree instance. The instance <mstid> is a number that corresponds to the desired existing multiple spanning tree instance.
  • Page 97: Show Spanningtree Mst Port Summary

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software show spanningtree mst port summary This command displays the settings of one or all ports within the specified multiple spanning tree instance. The parameter <mstid> indicates a particular MST instance. The parameter <slot.port/ all>...
  • Page 98: User Account Management Commands

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software VLAN Identifier Associated Instance User Account Management Commands These commands manage user accounts. show users This command displays the configured user names and their settings. This command is only available for users with readwrite privileges.
  • Page 99: Config Users Passwd

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config users passwd This command changes the password of an existing operator. The password is up to eight alphanumeric characters. The name and password are not case-sensitive. When a password is changed, a prompt will ask for the operator’s former password. If none, press enter.
  • Page 100: Config Users Snmpv3 Accessmode

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config users snmpv3 accessmode This command specifies the snmpv3 access privileges for the specified login user. The valid accessmode values are readonly specified access mode will apply. Default...
  • Page 101: Config Radius Maxretransmit

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config radius maxretransmit This command sets the maximum number of times a request packet is retransmitted when no response is received from the RADIUS server. The maxretransmit value is an integer in the range of 1 and 15.
  • Page 102: Config Radius Accounting Server Add

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Format config radius accounting server add This command configures the IP address to use for the accounting server. Only a single accounting server can be configured. If an accounting server is currently configured it must be removed using the ‘config radius accounting server remove’...
  • Page 103: Config Radius Server Add

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config radius server add This command configures the IP address to use to connect to a RADIUS server. Up to 3 servers can be configured per RADIUS client. If the maximum number of configured servers has been reached, this command will fail until one of the servers is removed using the ‘config radius server...
  • Page 104: Config Radius Server Primary

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config radius server primary This command specifies which configured server should be the primary server for this RADIUS client. The primary is the server that is used by default for handling RADIUS requests. The remaining configured servers are used only if the primary server cannot be reached.
  • Page 105: Show Radius Server Stats

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Current IP address Port Type Secret Configured show radius server stats This command displays the statistics for a configured RADIUS server. The IP address specified must match the IP address of a configured RADIUS server.
  • Page 106: Show Radius Accounting Summary

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software show radius accounting summary This command displays the configured accounting mode and accounting server. Format Mode IP address Port Secret Configured show radius accounting stats This command displays the statistics for the accounting server. The IP address specified must match that of a configured accounting server.
  • Page 107: Show Radius Stats

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software show radius stats This command displays the RADIUS statistics that are not related to a specific server or to the accounting server. Format Invalid Server Addresses clear radius stats This command clears all RADIUS statistics.
  • Page 108: Config Dot1X Port Controldir

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config dot1x port controldir This command configures the control direction for the specified port or ports. The control direction dictates the degree to which protocol exchanges take place between Supplicant and Authenticator.
  • Page 109: Config Dot1X Port Transmitperiod

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config dot1x port transmitperiod This command sets the value, in seconds, of the timer used by the authenticator state machine on the specified port to determine when to send an EAPOL EAP Request/Identity frame to the supplicant.
  • Page 110: Config Dot1X Port Reauthenabled

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Default Format config dot1x port reauthenabled This command enables or disables reauthentication of the supplicant for the specified port. The reauthenabled value must be ‘true’ or ‘false’. If the value is ‘true’ reauthentication will occur.
  • Page 111: Show Dot1X Port Stats

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Protocol Version PAE Capabilities Authenticator PAE State Backend Authentication State Quiet Period Transmit Period Supplicant Timeout Server Timeout Maximum Requests Reauthentication Period Reauthentication Enabled Key Transmission Enabled Control Direction show dot1x port stats This command displays the dot1x statistics for a specified port.
  • Page 112: Clear Dot1X Port Stats

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software EAPOL Frames Transmitted The number of EAPOL frames of any type that have been transmitted by this EAPOL Start Frames Received EAPOL Logoff Frames Received Last EAPOL Frame Version...
  • Page 113: Config Authentication Login Delete

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Default Format config authentication login delete This command deletes the specified authentication login list. The attempt to delete will fail if any of the following conditions are true: •...
  • Page 114: Config Dot1X Defaultlogin

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config dot1x defaultlogin This command assigns the authentication login list to use for nonconfigured users for 802.1x port security. This setting is overridden by the authentication login list assigned to a specific user if the user is configured locally.
  • Page 115: Config Users Login

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software config users login This command assigns the specified authentication login list to the specified user for system login. must be a configured <user> If the user is assigned a login list that requires remote authentication, all access to the interface from all CLI, web, and telnet sessions will be blocked until the authentication is complete.
  • Page 116: Show Users Authentication

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software User show users authentication This command displays all user and all authentication login information. It also displays the authentication login list assigned to the default user. Format User System Login 802.1x Port Security...
  • Page 117: Transfer Upload Serverip

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Format transfer upload serverip This command sets the IP address of the server on which the file is located. Note: This command is valid only when the transfer mode is TFTP. See “transfer upload mode” .
  • Page 118: Transfer Upload Filename

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software transfer upload filename This command sets the name for the file that is uploaded from the switch. The switch “remembers” the last file name used. Append the file path to the file name if the string is less than 31 characters. Otherwise, use the “transfer upload path”...
  • Page 119: Transfer Download Serverip

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software transfer download serverip This command configures the IP address of the server on which the file is located. Note: This command is valid only when the transfer mode is TFTP. See “transfer download mode”...
  • Page 120: Transfer Download Start

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software transfer download start This command starts a download transfer after displaying current settings and upon confirmation. Format clear transfer This command resets the file transfer configured values to the factory defaults.
  • Page 121: Clear Lag

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software clear lag This command clears all LAGs. Format clear stats port This command clears the stats for a specified <slot.port> Format clear stats switch This command clears the stats for the switch.
  • Page 122: Ping

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software ping This command checks if another computer is on the network and listens for connections. To use this command, configure the switch for network (in-band) connection (as described in the FASTPATH 2402/4802 Hardware User Guide).
  • Page 123: Differentiated Services

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Chapter 8 Differentiated Services This chapter contains the Command Line Interface (CLI) commands used for the QOS Differentiated Services (DiffServ) package. The GSM7224 Layer 2 Managed Switch provides a simplified interface for enabling DiffServ support.
  • Page 124 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Differentiated Services 202-10010-01...
  • Page 125: Appendix A Cabling Guidelines

    Appendix A Cabling Guidelines This appendix provides specifications for cables used with a NETGEAR GSM7224 Layer 2 Managed Switch. Fast Ethernet Cable Guidelines Fast Ethernet uses UTP cable, as specified in the IEEE 802.3u standard for 100BASE-TX.The specification requires Category 5 UTP cable consisting of either two-pair or four-pair twisted insulated copper conductors bound in a single plastic sheath.
  • Page 126: Category 5 Cable

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Category 5 Cable Category 5 distributed cable that meets ANSI/EIA/TIA-568-A building wiring standards can be a maximum of 328 feet (ft.) or 100 meters (m) in length, divided as follows: 20 ft.
  • Page 127: Twisted Pair Cables

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Table 8-1. Electrical Requirements of Category 5 Cable SPECIFICATIONS Number of pairs Impedance Mutual capacitance at 1 KHz Maximum attenuation (dB per 100 m, at 20° C) NEXT loss (dB minimum)
  • Page 128: Patch Panels And Cables

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Figure 8-2 illustrates crossover twisted pair cable. Figure 8-2: Crossover Twisted-Pair Cable Patch Panels and Cables If you are using patch panels, make sure that they meet the 100BASE-TX requirements. Use Category 5 UTP cable for all patch cables and work area cables to ensure that your UTP patch cable rating meets or exceeds the distribution cable rating.
  • Page 129: Using 1000Base-T Gigabit Ethernet Over Category 5 Cable

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Note: Flat “silver satin” telephone cable may have the same RJ-45 plug. However, using telephone cable results in excessive collisions, causing the attached port to be partitioned or disconnected from the network.
  • Page 130: Near End Cross Talk (Next)

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Unlike 10BASE-T and 100BASE-TX, which use only two of the four pairs of wires within the Category 5, 1000BASE-T uses all four pairs of the twisted pair. Make sure all wires are tested ⎯...
  • Page 131 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Figure 8-4 shows the RJ-45 plug and RJ-45 connector. Figure 8-4: RJ-45 Plug and RJ-45 Connector with Built-in LEDs Table 8-1 lists the pin assignments for the 10/100 Mbps RJ-45 plug and the RJ-45 connector.
  • Page 132: Conclusion

    User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Table 8-2. 100/1000 Mbps RJ-45 Plug and RJ-45 Connector Pin Assignments CHANNEL Conclusion For optimum performance of your 1000BASE-T product, it is important to fully qualify your cable installation and ensure it meets or exceeds ANSI/EIA/TIA-568-A:1995 or ISO/IEC 11801:1995 Category 5 specifications.
  • Page 133: Appendix B Glossary

    Appendix B Glossary Use the list below to find definitions for technical terms used in this manual. Numeric 802.1D The IEEE designator for Spanning Tree Protocol (STP). STP, a link management protocol, is part of the 802.1D standard for media access control bridges. Using the spanning tree algorithm, STP provides path redundancy while preventing endless loops in a network.
  • Page 134 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software 100BASE-TX The IEEE specification for 100 Mbps Fast Ethernet over Category 5 twisted-pair cable. 1000BASE-SX The IEEE specification for 1000 Mbps Gigabit Ethernet over fiber-optic cable. 1000BASE-T The IEEE specification for 1000 Mbps Gigabit Ethernet over Category 5 twisted-pair cable.
  • Page 135 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Baud The signaling rate of a line, that is, the number of transitions (voltage or frequency changes) made per second. Also known as line speed. BootP See “Bootstrap Protocol” on page 3.
  • Page 136 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software See “Command Line Interface” on page 4. Collision A term used to describe two colliding packets in an Ethernet network. Collisions are a part of normal Ethernet operation, but a sudden prolonged increase in the number of collisions can indicate a problem with a device, particularly if it is not accompanied by a general increase in traffic.
  • Page 137 A descriptive name for an address or group of addresses on the Internet. Domain names are of the form of a registered entity name plus one of a number of predefined top level suffixes such as .com, .edu, .uk, etc. For example, in the address mail.NETGEAR.com, mail is a server name and NETGEAR.com is the domain. DVMRP See “DNS”...
  • Page 138 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Ethernet A LAN specification developed jointly by Xerox, Intel and Digital Equipment Corporation. Ethernet networks transmit packets at a rate of 10 Mbps. Fast Ethernet An Ethernet system that is designed to operate at 100 Mbps.
  • Page 139 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software GARP See “Generic Attribute Registration Protocol” on page 7. GARP Information Propagation GIP is the propagation of information between GARP participants for the same application in a bridge is carried out by a GIP component.
  • Page 140 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software GVRP See “GARP VLAN Registration Protocol” on page 7. Half-duplex A system that allows packets to transmitted and received, but not at the same time. Contrast with full-duplex.
  • Page 141 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software IP Multicasting Sending out data to distributed servers on the MBone (Multicast Backbone). For large amounts of data, IP Multicast is more efficient than normal Internet transmissions because the server can broadcast a message to many recipients simultaneously.
  • Page 142 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Local Area Network A communications network serving users within a limited area, such as one floor of a building. A LAN typically connects multiple personal computers and shared network devices such as storage and printers.
  • Page 143 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software MDI/MDIX In cable wiring, the concept of transmit and receive are from the perspective of the PC, which is wired as a Media Dependant Interface (MDI). In MDI wiring, a PC transmits on pins 1 and 2. At the hub, switch, router, or access point, the perspective is reversed, and the hub receives on pins 1 and 2.
  • Page 144 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software them, and are the only areas that can contain an ASBR. Compare with stub area. See also ASAM and OSPF. (Cisco Systems Inc.) Open Systems Interconnection OSI is a seven (7) layer architecture model for communications systems developed by the ISO for the interconnection of data communications systems.
  • Page 145 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software packet bound for or heading away from the first port will be forwarded onto the second port as well. The administrator places a protocol analyzer on the port receiving the mirrored data to monitor each segment separately.
  • Page 146 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Using RADIUS, you must enter your user name and password before gaining access to a network. This information is passed to a RADIUS server, which checks that the information is correct, and then authorizes access.
  • Page 147 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software SNMPsec (historic): Security is based on parties. Few, if any, vendors implemented this version of the protocol, which is now largely forgotten. SNMPv2p (historic): For this version, much work was done to update the SNMPv1 protocol and the SMIv1, and not just security.
  • Page 148 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Spanning Tree Protocol. See “802.1D” on page 1 for more information. stub area OSPF area that carries a default route, intra-area routes, and interarea routes, but does not carry external routes.
  • Page 149 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Trunking The process of combing a set of trunks that are traffic-engineered as a unit for the establishment of connections between switching systems in which all of the communications paths are interchangeable.
  • Page 150 User Manual for the NETGEAR 7200 Series Layer 2 Managed Switch Software Wide Area Network A WAN is a computer network that spans a relatively large geographical area. Typically, a WAN consists of two or more local-area networks (LANs). Windows Internet Naming Service WINS.
  • Page 151 Address Resolution Protocol. See ARP cache, displaying 7-3 authentication login create 7-70 login delete 7-71 login set 7-71 show login info 7-73 show login users 7-73 Authentication Flag 7-21 Auto MDI/MDI-X 10-2 Auto Uplink 10-2 baud rate 7-16 boot code 7-79 Bootstrap Protocol (BOOTP) 7-14 broadcasts broadcast storm recovery mode 7-24...
  • Page 152 config protocol vlan remove 7-34 config radius accounting mode 7-59 config radius accounting server add 7-60 config radius accounting server port 7-60 config radius accounting server remove 7-60 config radius accounting server secret 7-60 config radius maxretransmit 7-59 config radius server add 7-61 config radius server msgauth 7-62 config radius server port 7-61 config radius server primary 7-62...
  • Page 153 7-35 GVRP enabling or disabling 7-37 join time 7-37 leave time 7-37 How to Use This Document 1-1 http Index //www.netgear.com/ 1-ii Hyper Terminal 4-2 IEEE 802.1Q 7-32 igmpsnooping adminmode 7-39 groupmembershipinterval 7-39 interface mode 7-40 maxresponse 7-39...
  • Page 154 adddest 7-45 addsrc 7-44 create 7-43 deldest 7-45 delsrc 7-44 remove 7-44 show 7-43 Management Access 2-1 management commands 201 commands 7-13 to 7-22 MDI/MDI-X 10-2 MDI/MDI-X wiring 10-11 mfdb gmrp 7-40 igmpsnooping 7-41 staticfiltering 7-41 stats 7-42 table 7-40 mirroring create 7-42 delete 7-43...
  • Page 155 server stats 7-63 server summary 7-62 stats 7-65 summary 7-62 timeout 7-59 reset system command 7-79 root traps 7-21 routing default router IP address, setting 7-16 save config command 7-58, 7-74 Security Commands 7-58 security commands 7-58 to 7-74 serial communication settings 7-15, 7-16 service port configuration 201 commands 7-16 sessions...
  • Page 156 show sysinfo 7-2 show telnet 7-22 show trapflags 7-20 show traplog 7-12 show users 7-56 show users authentication 7-74 show vlan detailed 7-29 show vlan interface 7-32 show vlan summary 7-29, 7-55 SNMP 2-2 SNMP communities access rights 7-17 adding 7-18 client IP masks 7-18 deleting 7-18 information 7-17...
  • Page 157 TFTP setting as download mode 7-76 setting as upload mode 7-74 timeouts forwardingdb 7-23 serial 7-16 TIP 4-2 topology change notification traps 7-21 transfer commands transfer download datatype 7-77 transfer download filename 7-77 transfer download mode 7-76 transfer download path 7-77 transfer download serverip 7-77 transfer download start 7-78 transfer upload datatype 7-76...
  • Page 158 XMODEM setting as download mode 7-76 setting as upload mode 7-74 ZTerm 4-2 Index...

This manual is also suitable for:

Gsm7224

Table of Contents