Built-In - Asko T754C W Operating Instructions Manual

Hide thumbs Also See for T754C W:
Table of Contents

Advertisement

Installation instructions

Built-in

ASKO dryers can be installed beneath a cabinet
or worktop with a minimum height of 34" (864
mm). There must be a gap of about 1/2" (12 mm)
all around the machine and a minimum gap of 1"
(25 mm) between the rear edge of the machine
top panel and the back wall. The opening
width must be at least 24-1/2" (622 mm). The
condensing models work best when they have
good air circulation.
Install the dryer so the condensed water will
continuously fl ow into a drain or sink, you
will need a drain outlet behind the unit. The
maximum drain height is 40" (1016 mm).
NOTE!
The height adjustment for the dryer is 33- 1/2"
to 34-1/2" (850 mm to 876 mm). Do not raise it
higher than 34-1/2" (876 mm).
NOTE!
It is very important to avoid a buildup of heat.
The warm air which is expelled from the rear of
the dryer must be able to dissipate.
Warm air which cannot dissipate could cause a
fault.
24
A buildup of heat could be avoided by:
• Creating a gap for the dryer in the kitchen
furniture plinth facing.
• Creating ventilation gaps in the kitchen unit.
When build under, drying times may be longer.
NOTE!
The dryer should not be installed next to a
refrigeration appliance. The warm air expelled
from the rear of the dryer would increase the
temperature around the refrigeration appliance
heat exchanger causing the compressor to
run continuously. If it is not possible to install
the dryer anywhere else, then the refrigeration
appliance must be sealed off from the dryer.
Customer Care Center
1-800-898-1879
www.askona.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

T744w cdT754 w

Table of Contents