Installation; Important Message; For Your Safety; Before You Start - Regency IG35-NG Owners & Installation Manual

Hide thumbs Also See for IG35-NG:
Table of Contents

Advertisement

IMPORTANT
MESSAGE
The Regency Gas Fireplace must be installed
in accordance with these instructions. Carefully
read all the instructions in this manual first.
Note: Failure to follow these instructions
could cause a malfunction of the
heater which could result in death,
serious bodily injury, and/or prop-
erty damage. Failure to follow these
instructions may also void your fire
insurance and/or warranty.

FOR YOUR SAFETY

This appliance requires air for proper combus-
tion. Always provide adequate combustion and
ventilation air. Follow instructions and informa-
tion in the current AS5601-2004, NZS 5261
or local codes. Consult the "authority having
jurisdiction" to determine the need for a permit
prior to starting the installation.

MATERIALS REQUIRED

A 240 Volt AC power cord is hooked up to the
unit. Plug 3 wire cord into a suitable receptacle.
Do not cut the ground terminal off under any
circumstances.
When connected with 240 volts, the appliance
must be electrically grounded in accordance
with local codes.
This unit is polarity sensitive and will not oper-
ate if polarity is incorrect.
Regency IG35 Gas Inbuilt Fireplace

BEFORE YOU START

Installation is to be carried out ONLY by an
authorised person.
1) The appliance shall be installed in accord-
ance with the manufacturer's installation
instructions, local gas fitting regulations,
municipal building codes, water supply
regulations, electrical wiring regulations,
with AS5601-2004. (AGA gas installation
code) NZS 5261(New Zealand)
2) Installation and repair should be done
ONLY by an authorised person.
3) The appliance should be inspected before
use and at least annually by an authorised
service person. More frequent cleaning may
be required due to excessive lint from carpet-
ing, bedding material, etc. It is imperative
that control compartments, burners and
circulating air passageways of the appliance
be kept clean and free from excessive lint
from carpeting.
4) See general construction and assembly
instructions. This appliance may only be in-
stalled in a flued, non-combustible fireplace.
The appliance and flue should be enclosed
when installed or passing through a living
area, where children may come in contact
with it.
This appliance can also be installed into the
approved Zero Clearance Kit #486-900 in a
combustible situation.
5) Always connect this space heater to a chim-
ney and flue to the outside of the building
envelope. Never flue to another room. Make
sure that the flue is properly sized and is
of adequate height to provide the proper
draft.
6) Inspect the flueing system annually for
blockage and any signs of deterioration.
7) Any safety glass removed for servicing
must be replaced prior to operating the ap-
pliance.
8) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
fireplace.
9) Installer must mechanically attach the sup-
plied label to the inside of the firebox of the
fireplace into which the gas fireplace insert
is installed.
"WARNING: This fireplace has been converted
for use with a gas fireplace insert only and
cannot be used for burning wood or solid fuels
unless all original parts have been replaced,
and the fireplace re-approved by the authority
having jurisdiction."

INSTALLATION

INSTALLATION
CHECKLIST
The Regency Gas Insert is installed as listed
below.
1) Unit Location - refer to "Clearances to
Combustibles" section.
2) Make the gas connections. Refer to "Gas
Connections" section.
3) Install the flue or liner to the flue collar. Refer
to "Flueing" section.
4) Slide the unit into the fireplace.
5) Test gas pressure, refer to "Gas Pipe Pres-
sure Testing" section. Check aeration, refer
to "Aeration Settings" section.
6) Test for flue spillage, refer to "Test for Flue
Spillage" section.
7) Install the optional brick panels. Refer to
"Optional Brick Panels" section.
8) Install the log set. Refer to "Log Set instal-
lation" section.
9) Assemble and install the faceplate and trim
and louvres. Refer to "Faceplate, Trim &
Louvre" section.
10) Optional Premium Flush Front installation.
Refer to "Premium Flush Front Installation"
section.
11) Final check: Before leaving this unit with the
customer, the installer must ensure that the
appliance is firing correctly. This includes:
a) Clocking the appliance to ensure the
correct firing rate.
b) Adjusting the primary air, if required,
to ensure that the flame does not car-
bon.
c) Ensuring that the appliance is flueing
correctly. Refer to "Test for Flue Spillage"
section.