Operating Instructions; Shutdown Instructions; First Fire; Automatic Convection Fan Operation - Regency I35-NG Owners & Installation

Gas inbuilt
Table of Contents

Advertisement

OPERATING
INSTRUCTIONS
Before operating this appliance, proceed through
the following check list.
1) Read and understand these Instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the three pieces of door glass
are properly positioned. Never operate the
appliance with any of the glass removed or
with the door open.
5) Verify that all fl uing and the cap is unob-
structed.
6) Verify log placement. If the pilot cannot be
seen when lighting the unit - the logs or the
embers have been incorrectly positioned.
7) The unit should never to turned off and on
without a minimum of a 60 second wait.
LIGHTING
PROCEDURE
IMPORTANT: Gas on/off knob cannot be
turned from "PILOT" to "OFF" unless it is
partially depressed.
1) Turn burner OFF using "ON/OFF" switch.
2) Turn gas control knob so indicator points
to "OFF" position and allow 5 minutes for
any gas in the combustion chamber to
escape.
3) Turn gas control knob counterclockwise
so indicator points to the "PILOT" position.
Depress the gas control knob fully. Depress
the igniter button several times until the
pilot lights. After approximately one minute,
release the gas control knob. The pilot fl ame
should continue to burn. If the pilot does not
remain lit, repeat operation allowing a longer
period before releasing gas control knob.
4) When the pilot stays lit, turn the gas knob
further counterclockwise to the "ON" posi-
tion.
5) Use the ON/OFF switch, wall switch, thermo-
stat or remote control to turn on the unit.
6) Rotate the fl ame height regulator (Hi/Lo) to
adjust the fl ame height higher or lower.
Regency I35 Gas Inbuilt Fireplace

OPERATING INSTRUCTIONS

SHUTDOWN
INSTRUCTIONS
1) Turn OFF the fl ame switch.
2) Push in gas control knob slightly and turn to
"OFF" position.

FIRST FIRE

The FIRST FIRE is part of the paint curing proc-
ess. To ensure that the paint is properly cured,
it is recommended that you burn your fi replace
for at least four (4) hours the fi rst time you use it
with the fan on. When fi rst operated, the unit will
release an odour caused by the curing of the paint
and the burning off of any oils remaining from
manufacturing. Smoke detectors in the house
may go off at this time. Open a few windows
to ventilate the room for a couple of hours. The
glass may require cleaning.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS STILL HOT!
Note: When the glass is cold and the appli-
ance is lit, it may cause condensation
and fog the glass. This condensation
is normal and will disappear in a few
minutes as the glass heats up.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
During the fi rst few fi res, a white fi lm
may develop on the glass front as part
of the curing process. The glass should
be cleaned or the fi lm will bake on and
become very diffi cult to remove. Use a
non-abrasive cleaner and NEVER clean
the glass while it is hot.
AUTOMATIC
CONVECTION FAN
OPERATION
Set the fan speed on control panel at the top
left side of the unit to adjust to the desired
speed. The fan will turn on as the stove comes
up to operating temperature. After the unit has
been turned off and the unit cooled to below a
useful heat output range the fan will shut off
automatically.
ADJUSTING FLAME
HEIGHT
Your heater has an adjustable fl ame to tailor
the look and heat output to your specifi c needs.
It is adjusted by turning the fl ame adjustment
dial on the gas control valve.
Turn clockwise to adjust the fl ame higher,
counterclockwise for a lower fl ame.
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

I35-lpgI35-ulpg

Table of Contents