FRAMING DIMENSIONS

A *
Framing Depth *
B
Framing Height
C
Framing Width
D
Gas Connection Height
E
Gas Connection Inset
F
Gas Connection Opening Width
G
Gas Connection Opening Height
H
Minimum Height to Combustibles
* Framing depth measurement is noted with nailing strips (top & sides) set as far forward on the firebox as
possible. The nailing strips can be adjusted (on both sides) to allow for varying thicknesses in non-
combustible material and wall finishes.
**Finished material thickness includes: non combustible material, tile slate, etc.
(example framing = 20" - if 2" thick finishing material is used (on both sides)=16"
Part I
Steel studs
on edge
C
Steel studs
Note: Gas hookup is on vent side of unit.
HZ42STE Framing Dimensions
**minus 2X the finished material thickness
54" (1372mm) Horizontal /58" (1473mm) Vertical Vent
H
A
B
Finished
Floor
20" (508mm)
42" (1067mm)
3-7/16" (87mm)
4-7/8" (124mm)
3-1/2" (89mm)
2-5/8" (67mm)
42" (1067mm)
Part II
B
41" (1041mm)
Steel studs - for ease of installation of non combustible ma-
terial-after Part I is complete.
* Install after unit in place with gas connection, electrical and
venting completed.
center
of hole
C L
1/2" gap required between faceplate and finished wall.
Dangerous operating conditions will occur if this is not adhered to.
Regency Horizon™ HZ42STE-10 Gas Fireplace
installation
Important:
Determine the wall thickness prior to framing this
unit. The finished wall depending on thickness
would decrease the required clearance of 7 or 9
inches depending if this is horizontally vented/
Vertically vented so thought must be put into
the framing details.
If the finished wall is 1/2 inch–the framing
should be 1/2 inch deeper to accommodate
the finished wall.
Unit
Finished wall
C
8-1/2"
(216mm)
C L
IMPORTANT:
|
11
33"
(838mm)
25-1/2""
(648mm)
|
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hz42ste-lp10Hz42ste

Table of Contents