Chapter 3
Mode 1 Output Timing
The timing specifications for an output transfer in Mode 1 are as follows:
WR*
OBF*
INTR
ACK*
DATA
Name
Description
T1
WR* = 0 to INTR = 0
T2
WR* = 1 to output
T3
WR* = 1 to OBF* = 0
T4
ACK* = 0 to OBF* = 1
T5
ACK* pulse width
T6
ACK* = 1 to INTR = 1
All timing values are in nanoseconds.
© National Instruments Corporation
T3
T1
T2
Minimum
–
–
–
–
300
–
3-19
Signal Connections
T4
T6
T5
Maximum
450
350
650
350
–
350
Lab-PC+ User Manual