Analog Output Signal Connections; Figure 3-7. Analog Output Signal Connections - National Instruments DAQCard-1200 User Manual

Multifunction i/o card for the pcmcia bus
Hide thumbs Also See for DAQCard-1200:
Table of Contents

Advertisement

Chapter 3
Signal Connections

Analog Output Signal Connections

Load
Load
Front I/O Connector
DAQCard-1200 User Manual
2 V in unipolar mode. V
either mode.
Pins 10 through 12 of the front connector are the analog output signals
DAC0OUT, AGND, and DAC1OUT.
DAC0OUT is the voltage output signal for analog output channel 0.
DAC1OUT is the voltage output signal for analog output channel 1. AGND
is the ground-reference point for both analog output channels and analog
input.
The following output ranges are available:
Output signal range
Bipolar output
Unipolar output 0 to 10 V*
* Maximum load current
Figure 3-7 shows how to make analog output signal connections.
10
+
VOUT 0
11
VOUT 1
12
+

Figure 3-7. Analog Output Signal Connections

should remain within a range of –6 to +11 V in
in+
±5 V*
±1 mA for 12-bit linearity (per DAC)
DAC0OUT
AGND
DAC1OUT
Analog Output Channels
DAQCard-1200
3-14
Channel 0
Channel 1
© National Instruments Corporation

Hide quick links: