TracVision M5/M7 User's Guide
Chapter 3 - Settings
34
4b. TracVision M7 Only - Adjust the LNB clockwise or
counter-clockwise, until the skew arrow on the LNB
points to the skew angle that you determined earlier.
IMPORTANT!
Be sure to keep the LNB fully inserted in the choke feed to
ensure optimum performance.
Figure 3-7 TracVision M7 LNB Skew Angle Adjustment
LNB
Negative
Skews
0˚ Skew
5. Tighten the two M4 socket set screws to secure the LNB
in place. Apply 9 in-lbs (1 Nm) of torque, if possible.
6. Reinstall the radome.
7. Restore power to the TracVision system.
Choke Feed
0
Positive
Skews