Data Port Configuration - Multitech DataTalker DT101 Owner's Manual

Data/voice/fax concentrator
Table of Contents

Advertisement

7.10Data Port Configuration

Table 7-10. Data Port Configuration
Step
Procedure
1
Toggle DIP switch position 3 to the down (closed) position to enable the command port.
2
Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker.
Note: Any cables connected to the computer should be shielded to reduce interference.
3
Apply power to the DataTalker.
4
Apply power to the terminal or PC. Run the PC's communications software in terminal mode
and press ENTER twice to establish communications with the DataTalker. The Main Menu
appears:
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
5
Enter 1 and press ENTER. The Configurations menu is displayed:
Configurations
1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
6
Enter 1 and press ENTER to display the Data Port Configuration menu.
Data Port Configuration
1 - Async/Sync:
2 - Speed:
3 - Word Length:
4 - Stop Bits:
5 - Parity:
6 - Flow Control:
7 - Enq/Ack Flow Control:
8 - Echo:
9 - Pacing:
10 - EIA Pass Through:
11 - Pass Xon:
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
Async
19200
8
1
None
CTS
Off
Off
Off
Off
Off
Chapter 7 - Troubleshooting
105

Advertisement

Table of Contents
loading

Table of Contents