COMMON MESSAGES
Downlink Messages
Downlink messages are from the cloud to the sensor and are used to configure the sensor. The sensor initiates
downlink messages, since the sensor is typically sleeping with the radio turned off.
For LoRaWAN devices, a downlink can be received after any uplink within the receive window.
The following messages can be sent back to the sensor upon a downlink request.
Command
Payload
0x00
Not used
0x01
4 bytes
--
0-7 bytes
0xfc
3 bytes
General Configuration
Use the general configuration command to configure parameters that apply to all sensor types.
Byte
Description
0x00
Disable sensor events
0x01
Radio config
0x02
Supervisory period. Default 19 hours.
0x03
Sampling rate
Disable Sensor Events
The following table shows the disable sensor event bit definitions.
Bit
Description
7:1
Not used
0
Disable all sensor events
12
Description
Not used
General configuration
Sensor configuration, refer to the Sensor Specific Messages chapter
Advanced configuration
TM
Reveal