Paradox Magellan MG5050 Programming Manual page 8

Hide thumbs Also See for Magellan MG5050:
Table of Contents

Advertisement

SP7000 PCB Layout
Charge LED:
Charging and battery test LED
Status LED:
• Flash once every second = Normal
• Flashes ON 1 second and OFF 1 second = Any trouble
• Always ON = Panel is using phone line
• Fast flash 6 seconds after power up = Installer lock enabled
Press and hold the RESET button for five seconds. The
STATUS LED will start flashing. Within 2 seconds of this
flashing, press the reset switch again. The panel will
reset to default and restart.
PGM Trigger: This jumper allows you
to choose whether the solid state
relay PGMs are grounded (-), or give
out 12V (+).
Refer to AC Power
& Backup Battery
Connections on
page 61.
The "
" output will
BELL
shutdown if the current
exceeds 3A.
AUX Power
Refer to transformer requirements on page 61
for Aux. Power Output. To connect additional
wiring to auxiliary power, use the red (+) and
black (-) keypad connectors. Auxiliary power
will shut down if current exceeds 1.1A. If the
auxiliary output is overloaded and is shut down,
you must disconnect all loads from the output
for at least 10 seconds before reconnecting any
load back to the auxiliary output.
Connection for Self-Contained Bell/Siren
The sum of the current drawn from
the BELL and AUX must be limited
to 1.3A (40VA transformer strongly
recommended). Exceeding this
limit will overload the panel power
supply and lead to complete
system shutdown.
5
LEDs
Z9 Z10 Z11 Z12 C Z13 Z14 Z15 Z16 C
* If EOL is enabled: see
section [706] option [2].
For the keypad's zone
configurations, refer to
Installer Quick Menu on
page 65. Also refer to
keypad zone
connections on page 59.
*
Used for In-Field Firmware
upgrade through a 307USB
Direct Connect Interface. See
Connecting to WinLoad on
page 62 for details.
EBUS and Dialer used with:
VDMP3 plug-in voice module
for voice reporting
PCS100 GSM communicator
module
May be labeled
ADM2 on some
panels
Upper Inputs = Zones 9 to 16
Lower Inputs = Zones 1 to 8
Z1 Z2
Z3 Z4
C
Z5 Z6 Z7 Z8 C
Refer to Single Zone
Inputs on page 59
To provide maximum lightning
protection we strongly recommend
having separate earth connections
for the dialer and zone ground
terminals.
Max. amount of keypads = 15 keypads
Max. aux. current = 700 mA
Max. distance of keypad from panel = 76m (250 feet)
Max. total run of wire = 230m (750 feet)
Four pin connector can
be used for quick
installation of a keypad.
Paradox Memory Key
(PMC-4, PMC-5)
Disconnect telephone
line before servicing.
AWG#14 single
conductor solid
copper wire
To metallic
enclosure
For the keypad's zone configurations, refer to the
Installer Quick Menu. If EOL is enabled: see
section [706] option [2]. Also refer to Keypad Zone
Connections on page 59.
This equipment must be installed and
maintained by qualified service
personnel only.
For UL and C-UL warnings, refer to the
UL and C-UL Warnings section at the
back of the Reference & Installation
Manual.