For keypad zone programming, see page 31.
Zone Recognition (MG Series)
When expanding zones via ZX8, up to 3 ZX8 modules can be added to the system and are identified by the ZX8 3-position jumpers +1,
+9 and +17.
MG5000 No ATZ
Panel
Zone 1:
Panel Input 1
Zone 2:
Panel Input 2
Zone 3:
Input 1
Zone 4:
Input 2
ZX8
Zone 5:
Input 3
Jumper Zone 6:
Input 4
Panel + 1 Zone 7:
Input 5
Zone 8:
Input 6
Zone 9:
Input 7
Zone 10: Input 8
Zone 11: Input 1
Zone 12: Input 2
ZX8
Zone 13: Input 3
Jumper Zone 14: Input 4
Panel + 9 Zone 15: Input 5
Zone 16: Input 6
Zone 17: Input 7
Zone 18: Input 8
Zone 19: Input 1
Zone 20: Input 2
ZX8
Zone 21: Input 3
Jumper Zone 22: Input 4
Panel + 17 Zone 23: Input 5
Zone 24: Input 6
Zone 25: Input 7
Zone 26: Input 8
Zone 27: N/A
Zone 28: N/A
Zone 29: N/A
Zone 30: N/A
Zone 31: N/A
Zone 32: N/A
If a zone is already programmed and you assign a device to the same zone, a wireless zone will overwrite a keypad/hardwire
zone, and a keypad zone will overwrite a hardwire zone.
Zone Recognition (SP Series)
When expanding zones via ZX8, up to 3 ZX8 modules can be added to the system and are identified by the ZX8 3-position jumpers +1,
+9 and +17.
SP5500 No ATZ
Zone 1:
Panel Input 1
Zone 2:
Panel Input 2
Panel
Zone 3:
Panel Input 3
Zone 4:
Panel Input 4
Zone 5:
Panel Input 5
Zone 6:
Input 1
Zone 7:
Input 2
ZX8
Zone 8:
Input 3
Jumper Zone 9:
Input 4
Panel + 1 Zone 10: Input 5
Zone 11: Input 6
Zone 12: Input 7
17
See Quick Menus on page 65
MG5000 ATZ
Zone 1: Panel Input 1A
Panel
Zone 2: Panel Input 2A
Zone 3: Panel Input 1B
Zone 4: Panel Input 2B
Zone 5: Input 1
Zone 6: Input 2
ZX8
Zone 7: Input 3
Jumper
Zone 8: Input 4
Panel + 1 Zone 9: Input 5
Zone 10: Input 6
Zone 11: Input 7
Zone 12: Input 8
Zone 13: Input 1
Zone 14: Input 2
ZX8
Zone 15: Input 3
Jumper
Zone 16: Input 4
Panel + 9 Zone 17: Input 5
Zone 18: Input 6
Zone 19: Input 7
Zone 20: Input 8
Zone 21: Input 1
Zone 22: Input 2
ZX8
Zone 23: Input 3
Jumper
Zone 24: Input 4
Panel + 17 Zone 25: Input 5
Zone 26: Input 6
Zone 27: Input 7
Zone 28: Input 8
Zone 29: N/A
Zone 30: N/A
Zone 31: N/A
Zone 32: N/A
SP5500 ATZ
Zone 1: Panel Input 1A
Zone 2: Panel Input 2A
Zone 3: Panel Input 3A
Zone 4: Panel Input 4A
Panel
Zone 5: Panel Input 5A
Zone 6: Panel Input 1B
Zone 7: Panel Input 2B
Zone 8: Panel Input 3B
Zone 9: Panel Input 4B
Zone 10: Panel Input 5B
Zone 11: Input 1
Zone 12: Input 2
MG5050 No ATZ
Zone 1:
Panel Input 1
Zone 2:
Panel Input 2
Panel
Zone 3:
Panel Input 3
Zone 4:
Panel Input 4
Zone 5:
Panel Input 5
Zone 6:
Input 1
Zone 7:
Input 2
ZX8
Zone 8:
Input 3
Jumper Zone 9:
Input 4
Panel + 1 Zone 10: Input 5
Zone 11: Input 6
Zone 12: Input 7
Zone 13: Input 8
Zone 14: Input 1
Zone 15: Input 2
ZX8
Zone 16: Input 3
Jumper Zone 17: Input 4
Panel + 9 Zone 18: Input 5
Zone 19: Input 6
Zone 20: Input 7
Zone 21: Input 8
Zone 22: Input 1
Zone 23: Input 2
ZX8
Zone 24: Input 3
Jumper Zone 25: Input 4
Panel + 17 Zone 26: Input 5
Zone 27: Input 6
Zone 28: Input 7
Zone 29: Input 8
Zone 30: N/A
Zone 31: N/A
Zone 32: N/A
SP6000 No ATZ
Zone 1:
Panel Input 1
Zone 2:
Panel Input 2
Panel
Zone 3:
Panel Input 3
Zone 4:
Panel Input 4
Zone 5:
Panel Input 5
Zone 6:
Panel Input 6
Zone 7:
Panel Input 7
ZX8
Zone 8:
Panel Input 8
Zone 9:
Input 1
Zone 10: Input 2
ZX8
Zone 11: Input 3
Jumper Zone 12: Input 4
MG5050 ATZ
Zone 1: Panel Input 1A
Zone 2: Panel Input 2A
Zone 3: Panel Input 3A
Zone 4: Panel Input 4A
Panel
Zone 5: Panel Input 5A
Zone 6: Panel Input 1B
Zone 7: Panel Input 2B
Zone 8: Panel Input 3B
Zone 9: Panel Input 4B
Zone 10: Panel Input 5B
Zone 11: Input 1
Zone 12: Input 2
ZX8
Zone 13: Input 3
Jumper Zone 14: Input 4
Panel + 1 Zone 15: Input 5
Zone 16: Input 6
Zone 17: Input 7
Zone 18: Input 8
Zone 19: Input 1
Zone 20: Input 2
ZX8
Zone 21: Input 3
Jumper Zone 22: Input 4
Panel + 9 Zone 23: Input 5
Zone 24: Input 6
Zone 25: Input 7
Zone 26: Input 8
Zone 27: Input 1
ZX8
Zone 28: Input 2
Jumper Zone 29: Input 3
Panel + 17 Zone 30: Input 4
Zone 31: Input 5
Zone 32: Input 6
SP6000 ATZ
Zone 1: Panel Input 1A
Zone 2: Panel Input 2A
Zone 3: Panel Input 3A
Zone 4: Panel Input 4A
Zone 5: Panel Input 5A
Zone 6: Panel Input 6A
Zone 7: Panel Input 7A
Panel
Zone 8: Panel Input 8A
Zone 9: Panel Input 1B
Zone 10: Panel Input 2B
Zone 11: Panel Input 3B
Zone 12: Panel Input 4B
Programming Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents