SP6000 PCB Layout
Charge LED:
Charging and battery test LED
Status LED:
• Flash once every second = Normal
• Flashes ON 1 second and OFF 1 second = Any trouble
• Always ON = Panel is using phone line
• Fast flash 6 seconds after power up = Installer lock enabled
PGM Trigger: This
jumper allows you to
choose whether the solid
state relay PGMs are
grounded (-), or give out
12V (+).
Refer to AC Power
& Backup Battery
Connections on
page 61.
The "
" output will
BELL
shutdown if the current
exceeds 3A.
AUX Power
Refer to transformer requirements on page 61 for
Aux. Power Output. To connect additional wiring to
auxiliary power, use the red (+) and black (-)
keypad connectors. Auxiliary power will shut down
if current exceeds 1.1A. If the auxiliary output is
overloaded and is shut down, you must
disconnect all loads from the output for at least 10
seconds before reconnecting any load back to the
auxiliary output.
Connection for Self-Contained Bell/Siren
The sum of the current drawn
from the BELL and AUX must be
limited to 1.3A (40VA transformer
strongly recommended).
Exceeding this limit will overload
the panel power supply and lead
to complete system shutdown.
When using an SP6000 panel in
conjunction with an RTX3, all K32
and K10V/H keypads must be
versions 2.0 or higher.
Magellan / Spectra SP
LEDs
EBUS and Dialer used with:
VDMP3 plug-in voice module for voice reporting
PCS100 GSM communicator module
* If EOL is enabled: see
section [706] option [2].
For the keypad's zone
configurations, refer to
Installer Quick Menu on
page 65. Also refer to
keypad zone
connections on page 59.
*
Used for In-Field Firmware
upgrade through a 307USB
Direct Connect Interface. See
Connecting to WinLoad on
page 62 for details.
Press and hold the
RESET button for five
seconds. The STATUS
LED will start flashing.
Within 2 seconds of
this flashing, press the
reset switch again. The
panel will reset to
default and restart.
Refer to Single Zone
Inputs on page 59
To provide maximum lightning
protection we strongly recommend
having separate earth connections
for the dialer and zone ground
terminals.
Max. amount of keypads = 15 keypads
Max. aux. current = 700 mA
Max. distance of keypad from panel = 76m (250 feet)
Max. total run of wire = 230m (750 feet)
Four pin connector can
be used for quick
installation of a keypad.
Paradox Memory Key
(PMC-4, PMC-5)
Disconnect telephone
line before servicing.
AWG#14 single
conductor solid
copper wire
To metallic
enclosure
For the keypad's zone configurations, refer to the
Installer Quick Menu. If EOL is enabled: see
section [706] option [2]. Also refer to Keypad Zone
Connections on page 59.
This equipment must be installed and
maintained by qualified service
personnel only.
For UL and C-UL warnings, refer to the
UL and C-UL Warnings section at the
back of the Reference & Installation
Manual.