Paradox Magellan MG5050 Programming Manual page 74

Hide thumbs Also See for Magellan MG5050:
Table of Contents

Advertisement

Warranty
For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. Your use of the Paradox product
signifies your acceptance of all warranty terms and conditions.
Limitations of Alarm Systems:
It must be understood that while your Paradox alarm system is highly advanced and secure, it does not offer any guaranteed protection against burglary, fire or other emergency
(fire and emergency options are only available on certain Paradox models). This is due to a number of reasons, including by not limited to inadequate or improper installation/
positioning, sensor limitations, battery performance, wireless signal interruption, inadequate maintenance or the potential for the system or telephone lines to be compromised or
circumvented. As a result, Paradox does not represent that the alarm system will prevent personal injury or property damage, or in all cases provide adequate warning or protection.
Your security system should therefore be considered as one of many tools available to reduce risk and/or damage of burglary, fire or other emergencies, such other tools include but
are not limited to insurance coverage, fire prevention and extinguish devices, and sprinkler systems.
We also strongly recommend that you regularly maintain your security systems and stay aware of new and improved Paradox products and developments.
TBR-21: In order to comply with TBR-21, standard force dialing must be enabled.
UL AND ULC WARNINGS
This equipment has the capability of being programmed with features not verified for use in UL installations. To stay within UL and ULC standards, the installer should use the
following guidelines when configuring the system:
All components of the system should be UL listed for the intended application.
If used for "Fire" detection, the installer should refer to NFPA Standards #72, Chapter 2. In addition, once installation is complete, the local fire authority must be notified of
the installation.
WARNING: This equipment must be installed and maintained by qualified service personnel only
This equipment must be verified by a qualified technician once every three years.
All keypads must use an anti-tamper switch.
Do not bypass fire zones.
Maximum allowed entry delay is 45 seconds.
Maximum allowed exit delay is 60 seconds.
Minimum 4 minutes for bell cut-off time.
The following features do not comply with UL requirements: Bypass Recall and Auto Trouble Shutdown.
Do not connect the primary indicating device to a relay. The installer must use the bell output.
To comply with UL985, the auxiliary power output should not exceed 200mA.
Do not connect the zone ground terminal with UL Listed products.
The metallic enclosure must be grounded to the cold water pipe.
All outputs are Class 2 or power-limited, except for the battery terminal.The Class 2 and power-limited fire alarm circuits shall be installed using CL3, CL3R, CL3P, or
substitute cable permitted by the National Electrical Code, ANSI/NFPA 70.
EOL resistor part #2011002000
For UL Installations: Universal UB1640W 16.5VAC min 40VA
All outputs are rated from 11.3Vdc to 12.7Vdc
12Vdc 4Ah rechargeable acid/lead or gel cell backup battery (YUASA model #NP7-12 recommended) for residential use. Use a 7Ah battery to comply with fire
requirements.
Wheelock 46T-12 siren
Legal
© 2008 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 7046142,
6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111, 5119069, 5077549 and RE39406. Canadian and international patents may also apply. Magellan and
Spectra SP are trademarks or registered trademarks of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents