16 - OpTIONS

Options
Air heat exchanger with pre-
treated fins
Low temperature glycol solution
Low temperature glycol solution
Very low noise level
Suction filter
Winter operation**
Soft starter
Frost protection down to -20°C
Partial heat reclaim
Master/slave operation
High-pressure single-pump
hydronic module
High-pressure dual-pump
hydronic module
Low-pressure single-pump
hydronic module
Low-pressure dual-pump hydronic
module
High-pressure variable-speed
single-pump hydronic module
High-pressure variable-speed
dual-pump hydronic module
High-pressure single-pump
hydronic module without
expansion tank
High-pressure dual-pump
hydronic module without
expansion tank
Low-pressure single-pump
hydronic module without
expansion tank
Low-pressure dual-pump hydronic
module without expansion tank
High-pressure variable-speed
single-pump hydronic module
without expansion tank
High-pressure variable-speed
dual-pump hydronic module
without expansion tank
JBus gateway
Bacnet gateway
LonTalk gateway
Water heat exchanger screw
connection sleeves
Welded water heat exchanger
connection sleeves
Remote Interface
*
30RQS/RQSY 039-160 with option 49 or 30RQS 0039-160 with option 6B.
** Winter operation option: This option allows operation of the unit down to -20°C outside air temperature due to the optimised control of the condensing temperature. One fan is equipped with a
frequency converter.
No.
Description
3A
Fins made of pre-treated aluminium
(polyurethane and epoxy)
5B
Low temperature chilled water production down
to 0°C with ethylene glycol and propylene
glycol. Note: With option 5B the units
are equipped with traditional coils (Cu/Al).
6B
Low temperature chilled water production down
to -15°C with ethylene glycol and -12°C with
propylene glycol. Note: With option 6B the units
are equipped with traditional coils (Cu/Al).
15LS
Acoustic compressor enclosure and low-speed
fans
23B
Washable G2 efficiency filter in accordance
with EN 779
28
Fan speed control via frequency converter
25
Electronic compressor starter
42
Electric heater on the hydronic module
49
Partial heat reclaim by desuperheating of the
compressor discharge gas.
58
Unit equipped with an additional field-installed
leaving water temperature sensor, allowing
master/slave operation of two units connected
in parallel
116B
Single high-pressure water pump, water filter,
expansion tank, temperature and pressure
sensors. See hydronic module option.
116C
Dual high-pressure water pump, water filter,
expansion tank, temperature and pressure
sensors. See hydronic module option.
116F
Single low-pressure water pump, water filter,
expansion tank, temperature and pressure
sensors. See hydronic module option.
116G Dual low-pressure water pump, water filter,
expansion tank, temperature and pressure
sensors. See hydronic module option.
116J
Single high-pressure water pump, water filter,
expansion tank, temperature and pressure
sensors. See hydronic module option.
116K
Dual high-pressure water pump, water filter,
expansion tank, temperature and pressure
sensors. See hydronic module option.
116R
Single high-pressure water pump, water filter,
temperature and pressure sensors. See
hydronic module option.
116S
Dual high-pressure water pump, water filter,
temperature and pressure sensors. See
hydronic module option.
116T
Single low-pressure water pump, water filter,
temperature and pressure sensors. See
hydronic module option.
116U
Dual low-pressure water pump, water filter,
temperature and pressure sensors. See
hydronic module option.
116V
Single high-pressure water pump, water filter,
temperature and pressure sensors. See
hydronic module option.
116W Dual high-pressure water pump, water filter,
temperature and pressure sensors. See
hydronic module option.
148B
Two-directional communications board,
complies with JBus protocol
148C
Two-directional communications board,
complies with Bacnet protocol
148D
Two-directional communications board,
complies with LonTalk protocol
264
Inlet/outlet screw connection sleeves
266
Welded inlet/outlet connection sleeves
275
Remotely installed user interface
(communication bus)
advantages
Improved corrosion resistance, recommended for marine
environments
Covers specific applications down to 0 °C
Covers specific applications such as ice storage and
industrial processes
Noise emission reduction at reduced fan speed
Prevents pollution of the air heat exchanger
Stable unit operation when the air temperature is between
-10°C and -20°C.
Reduced compressor start-up current
Hydronic module frost protection at low outside
temperatures
Free high-temperature hot-water production simultaneously
with chilled and hot-water production
Operation of two units connected in parallel with operating
time equalisation
Easy and fast installation
Easy and fast installation, operating safety
Easy and fast installation
Easy and fast installation, operating safety
Easy and fast installation, reduced power consumption of
the water circulation pump
Easy and fast installation, operating safety, reduced power
consumption of the water circulation pump
Easy and fast installation
Easy and fast installation, operating safety
Easy and fast installation
Easy and fast installation, operating safety
Easy and fast installation, reduced power consumption of
the water circulation pump
Easy and fast installation, operating safety, reduced power
consumption of the water circulation pump
Easy connection by communication bus to a building
management system
Easy connection by communication bus to a building
management system
Easy connection by communication bus to a building
management system
Permit connection of the unit to a screw connection
Permit connection of the unit to a connection other than a
Victaulic connection
Remote heat pump control up to 300 m
Use
30RQS/RQSY
039-160*
30RQS 039-160
30RQS 039-160
30RQS/RQSY
039-160
30RQSY
039-078
30RQS 039-160
30RQS/RQSY
039-080
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
30RQS/RQSY
039-160
39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

30rq 160 series30rqy 039 series30rqy 160 series

Table of Contents