INSTALLATION

6.1

Warnings

The use of gas appliances is
subject to statutory control; it is
essential to observe the current
regulations and laws in force
(see also chapter 5).
The appliance must discharge
combustion products directly
outside or into a suitable ex-
haust duct designed for this
purpose. Combustion products
must be discharged using origi-
nal fl ue kits only, since they are
integral parts of the boiler.
The appliance is not suitable for
receiving condensate coming
from the combustion products
evacuation system.
Before installing the boiler on an existing
c.h. system, fl ush it out thoroughly before
fi tting the boiler.
This procedure is to remove the presence of
any residues or impurities that could com-
promise good functioning of the boiler.
After washing it is necessary to treat the
plant.
The conventional warranty does not cover
any problems deriving from failure to com-
ply with such provisions.
For Propane, the appliance must also con-
form with the requirements of the distribu-
tors and comply with current Regulations
and laws in force.
The safety relief valve and the condensate
drain must be connected to a suitable drain,
or discharge in a safe manner.
INSTALLATION
The electrical wiring must conform with cur-
rent Regulations, in particular:
the boiler must be earthed using the cor-
rect bonding clamp.
a fused spur isolation switch, must be in-
stalled near to the boiler that allows com-
plete disconnection in overvoltage III cat-
egory conditions.
Refer to section "Electric connection" to
page 42 in this chapter for the electrical
connections.
In no circumstances will the manufac-
turer be held responsible if the warnings
and instructions contained in this manu-
al have not been complied with.
6.2
The boiler must be fi xed to a strong wall.
The dimensions for the exhaust fume duct
(detailed in section "Choice of fl u" to page
39 ) and the correct procedures for install-
ing the duct, depicted in the instruction
leafl et included with the fl ue kit, must be
complied with during installation.
To allow maintenance procedures it is
necessary to leave the minimum gaps in-
dicated in Fig. 6.1 .

Precautions for installation

The following prescriptions must
be respected for installation:
- 35 -