Biasi Activ A 18S User Manual And Installation Instructions page 64

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Hide thumbs Also See for Activ A 18S:
Table of Contents

Advertisement

ing keys 11 - 12 - 13 ( Fig. 7.41 ) for 10 sec-
onds at the same time until the letters Pr
that alternate with code 01 are displayed
on the LCD display, indicating that "param-
eter 01"( Fig. 7.42 ) has been activated.
Fig. 7.41
Fig. 7.42
Scroll the various parameters using keys
12 or 13 until the letters Pr that alternate
with code 12 are displayed on the LCD
display, indicating that "parameter 12"
( Fig. 7.43 ) has been activated.
- 64 -
COMMISSIONING
13
12
11
Fig. 7.43
Press keys
11 and 13 ( Fig. 7.41 ) at the
same time until the value of parameter
12 (99=Activ A 18S - Activ A 25S - Activ A
30S) is displayed on the LCD display ( Fig.
7.44 ).
Fig. 7.44
• t is possible to modify parameter using
I
keys 12 or 13 ( Fig. 7.41 ) (Refer to Fig.
7.40 and determine the correct Value ap-
pertaining to the output required for the
central heating requirement.).
By pressing key
11 ( Fig. 7.41 ) confi rmation
of the inserted value is obtained.
Press keys
11 and 12 ( Fig. 7.41 ) at the
same time to exit without changing the val-
ue (return to the parameters list Fig. 7.43 )
Press keys
11 - 12 - 13 ( Fig. 7.41 ) at the
same time for 10 seconds to exit the "pro-
gramming mode".