Technical Data Activ A 30S - Biasi Activ A 18S User Manual And Installation Instructions

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Hide thumbs Also See for Activ A 18S:
Table of Contents

Advertisement

4.7

Technical data Activ A 30S

Heat input
Nominal net
(A)
Nominal gross
(B)
(A)
Minimun net
Minimun gross
(B)
Useful output
Maximun
Minimun
Maximun condensing
Minimun condensing
- 28 -
TECHNICAL INFORMATION
kW
30,0
BTU/h
102356
kW
33,3
BTU/h
113615
kW
7,4
BTU/h
25248
kW
8,2
BTU/h
28025
kW
29,2
BTU/h
99626
kW
7,2
BTU/h
24565
kW
30,7
BTU/h
104744
kW
7,9
BTU/h
26954
Central heating
Min/Max fl ow temperature
settings*
Maximum pressure
Minimum pressure
Available head (in 1000 l/h)
Seasonal effi ency G20 (c)
Seasonal effi ency G31 (c)
* to the minimum useful output
(A)
referred to the net calorifi c value at 15 °C and
1013,25 mbar: G20 = 34,02 MJ/m3 - G31 = 46,34 MJ/
kg
(B)
referred to the gross calorifi c value at 15 °C and
1013,25 mbar: G20 = 37,78 MJ/m3 - G31 = 50,37 MJ/
kg
(C)
The value is used in the UK Government's Standard
Assessment Procedure (SAP) for energy rating
of dwellings. The test data from which it has been
calculated have been certifi ed by a notifi ed body.
(D)
Values subject to tolerance
Gas supply pressures
Gas
Natural G20
Propane G31
°C
25 - 85
kPa
250
bar
2,5
kPa
30
bar
0,3
kPa
33
bar
0,33
band
A
%
90,2
band
A
%
91,2
Pa
mbar
Nom
2000
20
Min
1700
17
Max
2500
25
Nom
3700
37
Min
2500
25
Max
4500
45