4.6 Hydraulic specifications
The hydraulic specifications in Fig. 4.4
represent the pressure (available head for the
central heating system) as a function of the
flow rate.
The load loss due to the boiler has already
been subtracted.
Output with thermostat cocks shut off
The boiler is fitted with an automatic by-pass
valve (41 on section 4.1), which protects the
primary heat exchanger.
In case of excessive reduction or total
blockage of water circulation in the central
heating system owing to closure of the
thermostatic valves or system component
cocks, the by-pass valve ensures a minimum
flow of water through the primary heat
exchanger.
4.7 Expansion vessel
The height difference between the pressure
relief valve and the highest point in the
system may be 10m at most.
For greater differences, increase the pre-load
pressure in the expansion vessel (40 on
section 4.1) and the system, when cold, by
0,1 bar for each additional 1m.
0,50
0,40
0,30
0,20
0,10
0,00
Fig. 4.4
4.6 Гидравлические
характеристики
l/h
Гидравлические характеристики на Рис .
4.5
представляют
( допустимый напор в системе отопления )
как функцию расхода воды .
Потери при загрузке бойлера уже учтены .
Мощность
термостатических клапанах
Котел
оснащен
пассным клапаном (41 на разделе 4.1)
оторый
предохраняет
теплообменник
В случае резкого уменьшения или полной
блокировки
циркуляции
отопления
термостатических клапанов или кранов
системы ,
бай - пассный
обеспечивает минимальный проток воды
через первичный теплообменник .
4.7 Расширительный бак
Разница
предохранительным клапаном и самой
высокой
точкой
превышать 10 метров .
При
большей
увеличить предварительное давление в
расширительном баке (40 на разделе 4.1 в
системе в ее холодном состоянии на 0,1
бара на каждый дополнительный 1 м .
Technical information
собой
давление
при
закрытых
автоматическим
первичный
в
системе
из - за
закрытия
клапан
высоты
между
системы
не
должна
разнице
необходимо
бай -
23