Comtech EF Data MBT-5003 Installation And Operation Manual page 85

L-band up/down converter system
Table of Contents

Advertisement

MBT-5003 L-Band Up/Down Converter System
Appendix A
Command
Arguments
Parameter
(Instruction
for Command
Type
Code and
or Response
Qualifier)
Enable
ESA=
1 byte
Statistics
Averaging
Enable
ESL=
1 byte
Statistics
Logging
Enable
ESW=
1 byte
Redundancy
Switch Mode
Description of Arguments
(Note that all arguments are ASCII numeric codes
to Query
Command or Query.
Enables or Disables averaging of statistics data at a rate of once
per second for 10 second. If Disabled, burst values will be logged
instead of averaged values.
0 = Disabled
1 = Enabled
Default Value: 0
Example: <1/ESA=0'cr'
>0001/ESA='cr''lf'
Command or Query.
Enables or Disables the statistics logging function.
0 = Disable
1 = Enable
Default Value: 0
Example: <1/ESL=1'cr'
>0001/ESL='cr''lf'
Command or Query.
Turns ON or OFF the redundancy state, where:
0 = Off
1 = On
Default value: 1
Example: <1/ESW=1'cr'
>0001/ESW='cr''lf'
between 48 and 57)
A–9
Response to
Query
Command
(Instruction
(Target to
Code and
controller)
qualifier)
ESA=
ESA?
ESA=x
ESA?
(Same format as command
arguments)
ESL=
ESL?
ESL=x
ESL?
(Same format as command
arguments)
ESW=
ESW?
ESW=x
ESW?
ESW *
Revision 1
MN-MBT5003
Response to query
(Target to controller)

Advertisement

Table of Contents
loading

Table of Contents